Plan NiuBoL ultrasonic wind meter installation for weather and PV stations. Check the mounting pipe, north reference and field acceptance before specifying accessories.
Tel/WhatsApp:+8615367865107
Email:Arvin@niubol.com +Nearly 100 partner companies in more than 75 countries. We are committed to providing high-quality, practical products to meet your needs and help you solve problems. Our products comply with international standards and are certified with ISO, CE and RoHS.Product Details
Quick Answer: NBL-W-21MUWS ultrasonic wind meter installation requires a rigid vertical support, a clear acoustic sensing region, geographic-north alignment and a receiver configured for both wind channels. The sensor uses 12-24 VDC and RS485 Modbus. A valid serial reply checks communication; it does not establish correct north orientation, unobstructed airflow or wind-measurement accuracy. Complete the mechanical and directional checks before using the station record.

Identify buildings, trees, poles, panels and the mast wake. Select height and boom geometry from the application method. A sensor can communicate correctly while measuring a local recirculation zone.
Walk the proposed position with the final mast accessories in mind. A solar panel, antenna or camera that is not on the initial sensor drawing can later occupy the same flow path. Record the direction and height of nearby obstructions so an unexpected wind pattern can be compared with the physical installation.
Distinguish the conditions to be measured from a convenient mounting point. A roof edge can have accelerated or recirculating flow; a position between PV rows can describe that local passage rather than open-field wind. The required measurement method should determine the mast and boom layout.
Keep radar and radio equipment in the exposure review. For this configuration, maintain more than 2 m separation from a radar scanning plane and review other interference sources. That separation is not a general guarantee of electromagnetic compatibility with every transmitter; check the actual site's equipment and operating conditions.
| Item | Configuration |
|---|---|
| Wind speed | 0-40 m/s; 0.01 m/s resolution |
| Wind direction | 0-360 degrees; 1 degree resolution |
| Speed accuracy | Low wind: +/-0.5 m/s; high wind: +/-1 m/s |
| Direction accuracy | Low wind: +/-3 degrees; high wind: +/-5 degrees |
| Supply and power | 12-24 VDC; 0.2 W |
| Interface | RS485 Modbus; 9600 baud |
| Housing and protection | Engineering plastic; IP65 |
| Operating environment | -40 to 70 degrees C; 0-100% RH |
| Dimensions and weight | 90 mm diameter x 140 mm; 0.6 kg |
| Mounting geometry | 50 mm installation diameter; three M5 fixing positions at 120 degrees |
Specify the applicable low- and high-wind accuracy conditions when agreeing a measurement comparison. The two accuracy entries do not define their transition speed by themselves. Do not interpret the 0.01 m/s increment as a tolerance of 0.01 m/s or promise that the finer value is meaningful under all conditions.
IP65 is the sensor housing rating. The completed installation still needs suitable cable entry, connection protection and mechanical support. No automatic heating, ice removal or three-dimensional wind measurement is established by this configuration.
Use a rigid vertical pipe and the specified fixing geometry. Keep the acoustic path unobstructed and route cable without pulling the housing. Check level and fastener security after mast installation.
For the corresponding mounting arrangement, the pipe has three equidistant M5 fixing positions, with the fixing position 7.5 mm from the upper end of the pipe. Match the supplied assembly and dimension drawing before drilling; do not infer the fixing diameter from the outside diameter of the sensor body.
Pass the cable through the mounting pipe where the arrangement requires it and provide strain relief. Connect the plug without twisting the cable, then secure the locking sleeve. The connector should not carry the weight or tension of a hanging cable run.
Check that fasteners do not distort the housing or enter the acoustic path. Keep the mounting tube vertical and the support rigid. A bracket that moves with wind changes the instrument's orientation and can alter both channel interpretation and the physical measurement.
Point the reference mark toward geographic north using a documented compass method. Confirm the platform's direction convention and record final orientation. Replacement must reproduce the same reference.
A magnetic compass observation needs the appropriate geographic reference method for the site. Keep the compass away from steelwork or energized equipment that can distort it. Record how the alignment was established, not only that the arrow was visually pointed along a convenient row or roof edge.
Before final acceptance, compare a known airflow direction with the reported direction. Check whether the receiving application expects the direction the wind comes from and whether an old offset remains in its configuration. A 180-degree reversal can look consistent on a compass graphic while still describing the opposite convention.
Use direction checks to establish orientation and mapping, not as a claim of angular calibration. A handheld fan, a short nearby streamer or a casual compass observation does not provide a traceable wind tunnel. Keep the accuracy comparison separate from these installation checks.
Verify the selected 12-24 VDC supply at the sensor, A/B polarity, baud rate, address, registers, units and scaling. Use a bus topology and suitable termination. Confirm local logging before enabling remote gateway transmission.
The NBL-W-21MUWS digital wind meter uses eight data bits and no parity at 9600 baud, with at least 1000 ms between communications. Match the delivered serial configuration and verify the two field definitions before copying settings to more instruments.
In the corresponding two-field format, speed is scaled by 0.01 m/s and direction by one degree. A speed integer of 272 therefore represents 2.72 m/s, not 27.2 m/s. Detect the 0x7FFF invalid/missing value before conversion rather than treating it as a valid high wind result.
Confirm the field at the local receiver and after remote export, including its observation time and quality. A gateway can transport an incorrectly decoded value just as reliably as a correct one. The broader system diagram below shows optional equipment, not additional functions included in the wind sensor.

Observe plausible calm, speed changes and direction shifts, preferably against a colocated reference. Verify restart after power interruption and flag missing records rather than filling them as calm wind.
| Observed behavior | Installation checks |
|---|---|
| Persistent direction offset | Review physical north, receiver convention and inherited software correction. |
| Values change when other mast equipment operates | Check supply at the sensor, cable routing, interference and grounding. |
| One wind sector looks different from an open reference | Compare mast, panel, building and vegetation wakes in that direction. |
| Near-zero speed with unstable direction | Review whether airflow supports a meaningful direction before labeling it a direction fault. |
| Remote value stays fixed after a bus interruption | Check record freshness and stale-value handling rather than assuming an unchanged display represents calm wind. |
A comparison reference should observe comparable airflow over the same interval. Mounting it behind the mast or below a nearby obstruction can create a difference unrelated to sensor error. Record the two positions and uncertainty of the comparison before deciding that an adjustment is justified.
Inspect the acoustic region for obstruction and contamination without disassembling or modifying the sensor. No rotating cups or bearings reduces mechanical service work, but it does not remove the need to inspect the mounting, cable, exposed surfaces and surrounding vegetation.
Retain photographs showing the north mark, support, nearby equipment and cable route. Record the final serial settings, address, channel conversion and any authorized directional offset. After service, verify those items before joining the replacement observations to the existing record.
For a PV mast, review the exposure when rows, trackers or accessories change. For a port, review radio equipment and exposed connections. For a building, record changes to rooftop plant that can alter flow. The wind meter can remain electrically healthy while the measurement environment changes.
Provide NiuBoL the proposed mast or pipe drawing, mounting height, obstructions, power and receiver for installation review. The station arrangement below illustrates one possible combination; it does not prescribe a universal mast height or include every accessory with the sensor.

The corresponding arrangement uses a 50 mm installation diameter and three M5 positions at 120 degrees. Match the delivered dimension drawing before making the pipe; the 90 mm sensor-body diameter is a different dimension.
Use an appropriate geographic-reference method, accounting for the site and magnetic disturbance. Record the method and verify the resulting direction at the receiver rather than relying on a visual alignment alone.
It can help check orientation and channel interpretation, but an uncontrolled fan setup is not a traceable speed or direction calibration. Use a suitable comparison method where accuracy acceptance is required.
No. Identify the invalid marker and communication loss separately from a valid near-zero speed observation. Otherwise the dataset can falsely record calm conditions during a failed channel.
No. Check physical reference, data map, scaling and receiver offset for the ultrasonic unit. A retained correction from the old instrument can introduce a direction error even if the new sensor is aligned correctly.
Identify the wind sensor, mounting adapter or pipe, cable and connector arrangement, surge protection and receiver. Provide the actual support drawing and service access so the quoted accessories match the installation.
Complete ultrasonic wind meter installation through mechanical fit, clear exposure, north alignment and two-channel verification. Keep direction checks distinct from calibration and invalid data distinct from calm wind. Send NiuBoL the mounting drawing and receiving configuration before ordering the installation accessories.
Sensors & Weather Stations Catalog
Agriculture Sensors and Weather Stations Catalog-NiuBoL.pdf
Weather Stations Catalog-NiuBoL.pdf
Agriculture Sensors Catalog-NiuBoL.pdf
Water Quality Sensor Catalog-NiuBoL.pdf
Related recommendations
Multi-Depth Soil Sensor RS485
TDR Soil Moisture Sensor
Pyranometer Solar Radiation Sensors
Soil ph sensor
Tipping Bucket Rain Gauge - ABS and Stainless Steel
Air Temperature and Humidity Sensor
Screenshot, WhatsApp to identify the QR code
WhatsApp number:+8615367865107
(Click on WhatsApp to copy and add friends)