— Products —
Consumer hotline +8618073152920 WhatsApp:+8615367865107
Address:Room 102, District D, Houhu Industrial Park, Yuelu District, Changsha City, Hunan Province, China
Weather Stations
NBL-W-THPLC 5 in1 temperature, humidity, pressure, and illumination CO2 sensor is a fully digital detection, high-precision sensor. It is integrated with high-precision digital temperature, humidity, air pressure, CO2 and high-sensitivity silicon blue photovoltaic detectors as illumination sensors. Quickly detect atmospheric temperature, atmospheric humidity, illuminance, CO2 and air pressure values, the built-in signal processing unit can output corresponding signals accordi···
Tel/WhatsApp:+8615367865107
Email:Arvin@niubol.com +Nearly 100 partner companies in more than 75 countries. We are committed to providing high-quality, practical products to meet your needs and help you solve problems. Our products comply with international standards and are certified with ISO, CE and RoHS.Product Details
The NBL-W-THPLC 5-in-1 temperature humidity pressure light CO2 sensor integrates five environmental measurements in one unit: air temperature, relative humidity, barometric pressure, illuminance and carbon dioxide concentration.
This multi-parameter environmental sensor measures temperature from -50 to 100°C, humidity from 0 to 100% RH, atmospheric pressure from 10 to 1100 hPa, illuminance from 0 to 200,000 Lux and CO2 from 0 to 2000 ppm. Combining five parameters in one device reduces the number of separate sensors required at each monitoring point.
For projects requiring a CO2 sensor with RS485 Modbus, the NBL-W-THPLC provides all five measurements through Modbus RTU communication and can connect to compatible PLCs, data loggers and IoT gateways. Typical applications include greenhouse monitoring, automatic weather station systems, agriculture and environmental monitoring.

| Parameter | Measurement Range | Accuracy | Resolution |
| Air Temperature | -50 to 100°C | ±0.5°C | 0.1°C |
| Relative Humidity | 0 to 100% RH | ±5% RH | 0.1% RH |
| Barometric Pressure | 10 to 1100 hPa | ±0.3 hPa | 0.1 hPa |
| Illuminance | 0 to 200,000 Lux | ±7% | 10 Lux |
| CO2 | 0 to 2000 ppm | ±(40 ppm + 2% F.S.) | 1 ppm |
| Model | NBL-W-THPLC |
| Product Type | 5-in-1 Multi-Parameter Environmental Sensor |
| Measured Parameters | Temperature, Humidity, Barometric Pressure, Illuminance, CO2 |
| Power Supply | DC 12V / DC 24V, depending on configuration |
| Output | RS485 |
| Protocol | Modbus RTU |
| Baud Rate | 9600 bps |
| Data Bits | 8 bits |
| Parity | None |
| Stop Bits | 1 or 2 bits |
| Minimum Communication Interval | 1000 ms |
| Operating Temperature | -50 to 80°C |
| Operating Humidity | 0 to 100% RH |
The NBL-W-THPLC combines five commonly required environmental parameters in one sensor. This allows a monitoring system to collect temperature, humidity, pressure, visible light and CO2 data from a single installation point and through one digital communication interface.
| Measurement | What It Measures | Typical Use |
| Air Temperature | Ambient air temperature | Weather, greenhouse and environmental monitoring |
| Relative Humidity | Atmospheric moisture as % RH | Agriculture, greenhouse and ambient monitoring |
| Barometric Pressure | Atmospheric pressure | Meteorological and environmental monitoring |
| Illuminance | Visible light intensity in Lux | Ambient light and greenhouse monitoring |
| CO2 | Carbon dioxide concentration in ppm | Greenhouse and environmental monitoring |
5-in-1 Measurement
Measures temperature, humidity, barometric pressure, illuminance and CO2 in one integrated device.
RS485 Modbus RTU
Provides a digital interface for integration with compatible PLCs, data loggers and IoT gateways.
Fewer Separate Sensors
Combining five parameters reduces the number of separate sensor units required at one monitoring point.
Multiple Monitoring Applications
Suitable for greenhouse, agriculture, weather and distributed environmental monitoring projects.
The NBL-W-THPLC is suitable for applications requiring a temperature humidity CO2 sensor with RS485 while also providing barometric pressure and illuminance measurements. A compatible controller can acquire all five values through the Modbus RTU interface.
| Communication Item | Specification |
| Interface | RS485 |
| Protocol | Modbus RTU |
| Baud Rate | 9600 bps |
| Read Function Code | 03 |
| Start Address | 0000 |
| Number of Registers | 5 |
| Register Sequence | Temperature → Humidity → Pressure → Illuminance → CO2 |
When several Modbus sensors share one RS485 bus, each device should use a unique communication address. The data logger, PLC or gateway should also provide sufficient time between polling commands.
NBL-W-THPLC → RS485 Modbus RTU → PLC / Data Logger / IoT Gateway → Cloud Platform or Private Server
The sensor itself provides measurement data through RS485. Remote transmission over 4G, Ethernet, Wi-Fi or LoRaWAN requires a compatible data logger or IoT gateway with the required communication method.

The NBL-W-THPLC can be used as a greenhouse CO2 sensor, a multi-parameter sensor within an automatic weather station system, or an environmental monitoring sensor where temperature, humidity, pressure, light and CO2 measurements are required from one monitoring point.
Greenhouse Monitoring
Agricultural Monitoring
Environmental Monitoring
Industrial Monitoring
Remote Monitoring Stations
IoT Monitoring Systems
Research Projects
| Item | Recommendation |
| Monitoring Location | Install the sensor at a location representative of the environment to be monitored. |
| Air Circulation | Keep the louver openings unobstructed so ambient air can circulate normally around the sensing elements. |
| Temperature Measurement | Avoid unintended local heat sources that could make the measurement unrepresentative of the surrounding environment. |
| CO2 Measurement | Avoid placing the sensor directly beside concentrated CO2 sources or exhaust outlets unless these are the intended monitoring targets. |
| Light Measurement | Install the sensor where the illuminance channel can represent the light conditions required by the project. |
| RS485 Network | Assign a unique Modbus address to each compatible sensor sharing the same RS485 bus. |
The light channel of the NBL-W-THPLC measures illuminance in Lux. Illuminance, PAR and solar irradiance are different measurement quantities and should not be treated as interchangeable when selecting a sensor.
| Measurement | Typical Unit | Recommended Sensor Type |
| Illuminance | Lux | NBL-W-THPLC integrated light channel |
| PAR / PPFD | µmol/m²/s | Dedicated PAR sensor |
| Solar Irradiance | W/m² | Pyranometer / solar radiation sensor |
| Monitoring Requirement | Recommended Selection |
| Temperature + Humidity + Pressure + Light + CO2 | NBL-W-THPLC 5-in-1 multi-parameter environmental sensor |
| Temperature + Humidity Only | Dedicated air temperature and humidity sensor |
| Plant Light / PPFD | PAR sensor |
| Solar Radiation in W/m² | Pyranometer / solar radiation sensor |
| Wind Speed, Wind Direction or Rainfall | Add corresponding weather sensors or select an integrated automatic weather station |
A1. It measures air temperature, relative humidity, barometric pressure, illuminance and carbon dioxide concentration in one integrated sensor.
A2. The CO2 measurement range is 0 to 2000 ppm with a resolution of 1 ppm.
A3. Yes. The NBL-W-THPLC provides RS485 communication using Modbus RTU at 9600 bps.
A4. Yes. A compatible PLC, data logger or IoT gateway with an RS485 Modbus RTU interface can read the five measurement values.
A5. Yes. Multiple compatible Modbus sensors can share one RS485 bus when each device uses a unique communication address and the network is wired and configured correctly.
A6. No. The integrated channel measures illuminance in Lux. Projects requiring photosynthetically active radiation or PPFD in µmol/m²/s should use a dedicated PAR sensor.
A7. No. Solar irradiance in W/m² requires a pyranometer or dedicated solar radiation sensor.
A8. Yes. It can provide CO2, temperature, humidity, pressure and illuminance data to a compatible greenhouse monitoring or control system. Automatic ventilation, CO2 dosing or other control actions require an external controller or software platform.
A9. The sensor itself provides RS485 measurement data. Remote 4G, Wi-Fi, Ethernet or LoRaWAN communication requires a compatible data logger or IoT gateway.
A10. No. It measures temperature, humidity, barometric pressure, illuminance and CO2, but it does not measure wind speed, wind direction or rainfall. These parameters require additional sensors or an integrated weather station.
NBL-W-THPLC-5in1-Temperature-Humidity-Pressure-Illumination-CO2-Sensor-Datasheet.pdf
For quotation and model selection, specify the required quantity, power supply, cable length, installation environment and the PLC, data logger or IoT gateway that will receive the RS485 Modbus data. If the project has specific requirements for communication, calibration, enclosure protection or certification, include these requirements with the inquiry.
Sensors & Weather Stations Catalog
Agriculture Sensors and Weather Stations Catalog-NiuBoL.pdf
Weather Stations Catalog-NiuBoL.pdf
Agriculture Sensors Catalog-NiuBoL.pdf
Water Quality Sensor Catalog-NiuBoL.pdf
Related recommendations
Wind Speed sensor Output Modbus/RS485/Analog/0-5V/4-20mA
Tipping bucket rain gauge for weather monitoring auto rainfall sensor RS485/Outdoor/stainless steel
5-in-1 Temperature, Humidity, Air Pressure, Illumination, CO2 Sensor
5-in-1 Ultrasonic Weather Station Sensor RS485 | NBL-W-51MUWS
6-in-1 Ultrasonic Weather Station Sensor with Rainfall | NBL-W-61MUWS
7-in-1 Ultrasonic Weather Sensor with Rainfall & illuminance | NBL-W-71MUWS
Screenshot, WhatsApp to identify the QR code
WhatsApp number:+8615367865107
(Click on WhatsApp to copy and add friends)