— Download —
Consumer hotline +8618073152920 WhatsApp:+8615367865107
Address:Room 102, District D, Houhu Industrial Park, Yuelu District, Changsha City, Hunan Province, China
All products
Compare NiuBoL carbon monoxide sensor price options for ambient monitoring. Review the 10 ppm CO channel, RS485 integration and calibration scope, then request a quote.
Tel/WhatsApp:+8615367865107
Email:Arvin@niubol.com +Nearly 100 partner companies in more than 75 countries. We are committed to providing high-quality, practical products to meet your needs and help you solve problems. Our products comply with international standards and are certified with ISO, CE and RoHS.Product Details
Quick Answer: A carbon monoxide sensor price is meaningful only after the quotation identifies what is being supplied: a sensing element, an assembled transmitter or a complete monitoring station. The NiuBoL diffusion multi-gas configuration includes a 0-10 ppm CO channel and RS485 Modbus RTU output. Compare that environmental monitoring package with equivalent equipment, not with a bare cell or a safety alarm whose range, approvals and functions are different.

This package measures ambient gas entering the housing by diffusion. The four electrochemical gas channels are CO, SO2, NO2 and O3; PM2.5 and PM10 can be included as particle channels. A data logger or RTU reads the measurements, while a separate gateway provides remote transmission where required. Neither a cellular subscription nor a complete alarm controller follows automatically from the sensor's RS485 interface.
| Item | Configuration specification | Effect on the quotation |
|---|---|---|
| CO span / resolution | 0-10 ppm / 0.001 ppm | Specify this span or identify a different required version explicitly. |
| Gas sensing / accuracy | Four-electrode electrochemical; +/-5% FS | Require performance suitable for the concentration changes the project must resolve. |
| Other gas channels | SO2, NO2 and O3, each 0-5 ppm | Identify the fitted channels rather than comparing different packages by unit price. |
| Particle options | PM2.5 0-1000 micrograms/m3; PM10 0-2000 micrograms/m3 | Confirm whether the optical particle hardware is included. |
| Supply / output | 12 VDC; RS485 Modbus RTU, 9600 bps | Price the power supply and acquisition equipment separately if needed. |
| Sampling / mounting | Diffusion; pole-mounted assembly | A pumped cabinet or duct arrangement is not the same supplied configuration. |
| Environment / housing | -30 to 50 degrees C; 15-90% RH; IP65 housing | Review condensation, exposure and the protection of external connections. |
| Power demand / cable material | Obtain the figures and cable specification for the ordered package | Needed for solar power design, extensions and exposed cable routes. |
For a 10 ppm full scale, +/-5% FS corresponds arithmetically to +/-0.5 ppm. It does not become +/-0.001 ppm because the output has three decimal places. If the project needs to distinguish much smaller ambient changes, request performance evidence at those concentrations before accepting the configuration. Buying more stations does not remove an unsuitable per-channel uncertainty.
Low-level ambient work and industrial leak detection need different ranges and evidence. State normal, alarm and maximum concentration so quotations do not contain unlike cells.
An industrial park may need CO trends at several boundary locations with other pollutant channels and weather context. A roadside project may prioritize comparable placement and time-averaged records. Those requirements fit an environmental monitoring discussion. A boiler-room protection project instead needs a complete, appropriately approved detection and alarm design; the ambient package's price and concentration span do not establish suitability for that duty.
State the expected background, the change of interest and the maximum credible concentration in the inquiry. Also identify whether the result is for investigation, operational indication or a prescribed reporting method. This lets the supplier reject an unsuitable span before procurement invests in the wrong logger, enclosure or installation design.
Ask each bidder to complete the same list and separate included equipment from options. A lower equipment total may simply omit the logger, particle channels or calibration work. Check those differences before negotiating a discount on quantities that do not represent the same monitoring point.
| Quotation line | What to identify | Common hidden difference |
|---|---|---|
| Gas measurement assembly | CO span, fitted gas channels, transmitter and enclosure. | A bare sensing cell compared with an assembled digital instrument. |
| Particles | Whether PM2.5/PM10 hardware and service are included. | A four-gas offer compared with a gas-and-particle package. |
| Acquisition | RTU/logger, usable inputs and local record storage. | RS485 output mistaken for a complete recording system. |
| Remote connection | Gateway, antenna, configuration and recurring connection costs. | Network hardware supplied without commissioning or service. |
| Installation | Bracket, mast, cable, power and external joint protection. | Supply-only equipment compared with an installed monitoring point. |
| Verification and support | Factory checks, field comparison, replacement parts and return procedure. | Different calibration or field-service obligations behind a similar warranty description. |
Separate sensor, enclosure, display, alarms, cable, mounting, logger, gateway, calibration, spares and service. This lets procurement compare equivalent scope and remove genuine options.
Request a current quotation for the defined order configuration. Historical prices, an unrelated sensing element or a different gas range are not reliable substitutes. Separate hardware, optional equipment and service totals so quantities and destination can be applied to the correct scope.

If an existing PLC or RTU has a usable RS485 port, a sensor-only package may avoid buying another logger. The integrator still needs the delivered register map, gas conversion factors, serial settings and a test that the archived CO value matches the sensor output. A free port is not proof that the driver is configured for this device.
For an unattended site without acquisition equipment, include a data logger or RTU, field power and the necessary communication gateway. Define whether local storage must continue during a network outage. The quotation should identify who commissions the gateway and receiving platform, rather than leaving both suppliers to assume the other party will complete the connection.
Relays and local sound/light alarms are separate functions from transmitting a numerical concentration. If those functions are required, specify the controller, alarm logic and applicable approvals. Do not infer relay contacts from the presence of Modbus, or assume a general-purpose remote dashboard is a personnel-protection system.
Define included zero/span work, gas certificates, field commissioning and future service. An inexpensive sensor without a workable calibration path can cost more over its life.
Separate a factory response check from a field comparison and from an adjustment made after installation. Ask which is included, who performs it and which record is delivered. An included certificate is useful only when it identifies the tested equipment and the relevant procedure; a generic company certificate does not establish the CO channel's performance.
For a multi-site order, request the replacement procedure before buying a large spare inventory. Clarify whether the replaceable item is a cell, a calibrated module or a complete exchange transmitter, and whether new coefficients or software configuration are needed. Storage conditions and shelf life also matter for spares; there is no defensible universal cell-replacement interval for every exposure.
Where an integrator already owns reference equipment and trained staff, the service arrangement may differ from a remote project requiring return-to-factory support. Ask for those alternatives separately. Avoid paying for duplicate field work while also avoiding an order in which neither party is responsible for checking the installed readings.
Direct insertion into a hot, wet exhaust stream is not established by an ambient diffusion specification. Nor does IP65 make the air inlet suitable for immersion, pressure washing or an uncontrolled process sample. A request for pumped or conditioned sampling needs a separate design review covering the sample path and the conditions reaching the measurement assembly.
For a prescribed compliance method or a safety function, provide the actual performance and approval requirements at the inquiry stage. NiuBoL can review the monitoring configuration against the application; do not replace that review with a broad statement that every industrial CO use is covered. A technically unsuitable low quotation remains unsuitable after a price reduction.
To request a comparable carbon monoxide sensor price, send the monitoring purpose, concentrations and units, required gas/particle channels, site conditions, existing logger details, cable distances and installation scope. Add quantity, destination and requested delivery schedule. Ask for the exact configuration and any exclusions to be stated with the offer.

They may cover different products: a cell, a transmitter or a complete station. Compare the gas span, fitted channels, acquisition, installation and verification scope first. Only then compare unit prices for equivalent quantities and delivery conditions.
No. It is an ambient diffusion monitoring configuration. The expected concentrations, required uncertainty and intended use must fit that span. Hot exhaust measurement, higher concentrations and safety alarms require separate technical assessment.
No. The stated gas accuracy is +/-5% of full scale, equivalent to +/-0.5 ppm for the 10 ppm CO channel. Evaluate the uncertainty relevant to the intended concentration changes instead of using the decimal display as an accuracy claim.
RS485 is the local connection to a compatible logger or controller. Remote access needs the gateway, network service and receiving system. Include those items in the quotation when they are not already available.
Define both, but do not assume one fixed package suits every site. Identify factory and field work, reference arrangements, replaceable parts and the support route. Request spare storage requirements before purchasing parts intended to remain unused for a long period.
Possibly, if its input or serial port, software and storage arrangement support the ordered transmitter. Confirm integration effort and who will test the final concentration records. Reusing hardware does not eliminate driver configuration and acceptance work.
Provide the application, concentration span, required channels, environment, sampling arrangement, output, existing acquisition equipment, quantity and destination. State installation, calibration and document requirements so the offer identifies what is included and what remains the buyer's responsibility.
Compare a carbon monoxide sensor price against a defined monitoring point. For the NiuBoL ambient multi-gas package, check the 10 ppm CO span and full-scale accuracy first, then compare acquisition, installation and service scope. An itemized quotation helps procurement distinguish a genuine cost difference from missing equipment or an unsuitable measurement specification.
Sensors & Weather Stations Catalog
Agriculture Sensors and Weather Stations Catalog-NiuBoL.pdf
Weather Stations Catalog-NiuBoL.pdf
Agriculture Sensors Catalog-NiuBoL.pdf
Water Quality Sensor Catalog-NiuBoL.pdf
Related recommendations
Multi-Depth Soil Sensor RS485
TDR Soil Moisture Sensor
Pyranometer Solar Radiation Sensors
Soil ph sensor
Tipping Bucket Rain Gauge
Air Temperature and Humidity Sensor
Screenshot, WhatsApp to identify the QR code
WhatsApp number:+8615367865107
(Click on WhatsApp to copy and add friends)