— Download —
Consumer hotline +8618073152920 WhatsApp:+8615367865107
Address:Room 102, District D, Houhu Industrial Park, Yuelu District, Changsha City, Hunan Province, China
All products
Integrate a NiuBoL industrial rain gauge with pulse or RS485 inputs. Check 0.2 mm event records, collector exposure and controlled-water acceptance before ordering.
Tel/WhatsApp:+8615367865107
Email:Arvin@niubol.com +Nearly 100 partner companies in more than 75 countries. We are committed to providing high-quality, practical products to meet your needs and help you solve problems. Our products comply with international standards and are certified with ISO, CE and RoHS.Product Details
Quick Answer: The NiuBoL industrial tipping bucket rain gauge measures liquid precipitation in 0.2 mm increments through a 200 mm collecting aperture. Select the pulse, voltage or RS485 version to match the receiving instrument. A usable rainfall record also depends on a level collector, correct counting and a controlled-water test; a connected gauge with a blocked funnel can still report zero.

| Item | Specification |
|---|---|
| Collecting aperture | 200 +/-0.6 mm |
| Intensity range | 0-4 mm/min |
| Resolution | 0.2 mm per tip, stated as 6.28 ml |
| Accuracy | +/-4% in indoor static test at 2 mm/min |
| Supply | 5 VDC or 12-24 VDC, depending on output |
| Outputs | Reed-switch pulse, 0-2.5V, 0-5V or RS485 |
| Cable | 5 m standard; longer cable optional |
| Operating temperature | 0 to 50 degrees C |
| Storage temperature | -40 to 80 degrees C |
Rain enters the calibrated aperture, passes through the funnel and alternately fills tipping buckets. Each tip equals a fixed depth. The logger counts events and converts them to accumulated rain or intensity. A blocked funnel, unlevel base or contact bounce changes the result even when the electronics remain online.
Ten completed tips represent 2 mm of accumulated rainfall. If the logger displays 2.000 mm, the extra decimal places do not improve the gauge's physical resolution. During light rain, water may remain in a partly filled bucket, so the first tip occurs after rainfall has started. The last part-bucket can also carry water across a reporting boundary.
Specify the required record before selecting a logger. Daily totals need reliable accumulation and an agreed day boundary. A storm study may also need the time of individual tips, subject to the recorder's capability. A rainfall-triggered action needs a defined accumulation window and reset rule, not simply a total that has increased since installation.
For example, three tips during five minutes equal 0.6 mm and an interval-average rate of 7.2 mm/h. That is not a measurement of the highest instantaneous rate during those five minutes. Short reporting intervals make the stepping more visible; selecting a faster upload interval does not change the bucket increment.
| Output | Receiver and acceptance check |
|---|---|
| Reed-switch pulse | Use a compatible counter input. Observe individual tips while checking that each completed tip produces one accepted count, without extra counts from contact bounce. |
| 0-2.5 V or 0-5 V | Use the matching voltage input and delivered conversion. Establish whether the transmitter value represents an interval or cumulative quantity before programming the calculation. |
| RS485 | Use the delivered Modbus RTU document. Check address, serial format, rainfall unit and counter behavior. Do not multiply an already scaled rainfall value by 0.2 again. |
The NBL-W-RS V4.0 digital rain gauge requires at least 1000 ms between communications. Confirm the delivered revision before configuring an RTU. RS485 describes the field interface; transmitting to a remote server requires a suitable logger or gateway.
A long pulse cable needs more than electrical continuity. Check the receiving input specification, cable routing, outdoor joints and surge exposure. Declare the required total cable length when ordering rather than modifying a factory cable without checking the effect on the selected output. Keep a rainfall counter separate from a wind-speed frequency input in the channel configuration.
Keep the gauge away from buildings, trees, fences and splashing surfaces according to the applicable siting method. The rim must be level and at the documented height. Service access matters because leaves, insects, dust and bird contamination need inspection.
A gauge below a roof edge may collect drainage rather than local precipitation; one beside irrigation sprinklers can record applied water. A taller mast can improve wind exposure while making rainfall collection and maintenance worse. Select the gauge position separately, even when it belongs to the same station.
Check level after tightening the foundation fixings, not only before them. Look inside for transport restraints and confirm the mechanism moves as instructed before testing the signal. Record the collector height and nearby obstacles so a later building extension or crop canopy can be recognized as a change in exposure rather than an unexplained change in rainfall.

Start by identifying the ordered bucket increment and following the manufacturer's preparation procedure. Inspect the funnel and tipping mechanism, level the instrument and establish the required starting condition. Count observed tips while the recorder is connected. This first check can expose a wrong input, disconnected reed switch or duplicate counting before a calibration adjustment is considered.
For a nominal 200 mm aperture, collecting area is approximately 314 cm2. A 0.2 mm rainfall depth over that area is approximately 6.28 ml; 20 tips represent 4 mm, or about 125.6 ml. These calculations explain the scale. They do not replace the prescribed calibration volume, delivery rate or handling of water remaining in a partly filled bucket.
Deliver water through the normal collection path at the procedure's specified rate. Emptying a bottle rapidly into the funnel tests a different condition and can conceal the reason for an error. If the observed tip count is correct but the logger total is wrong, inspect conversion, filtering and reporting boundaries before touching the bucket adjustment.
The stated +/-4% accuracy applies to the identified indoor test condition at 2 mm/min. It is not an unconditional outdoor accuracy claim. Wind around the aperture, splash, blockage and rainfall outside the specified intensity range affect how a field result should be interpreted.
If the receiving software calculates interval rainfall from successive totals, test the case in which the instrument or logger restarts. A smaller new total can mean a reset or rollover; subtracting it blindly can create negative rainfall. Identify where accumulation is held and whether it survives power loss on the delivered configuration.
For a hydrological station, synchronize rainfall with water-level or flow records and retain local recording during a network outage where the selected logger supports it. A delayed upload must keep the event time. Reprocessing the same uploaded total must not create a second rainfall event.
For agricultural monitoring, compare natural rainfall with irrigation records and soil response rather than assuming all collected rainfall became available root-zone water. At an industrial drainage site, use the local rainfall record with the drainage layout and level observations. One collector does not measure rainfall distribution across every part of a large catchment.
| Observed result | First field checks |
|---|---|
| Zero during known rain | Inspect inlet, funnel, transport restraint and bucket movement. Then compare the physical tip with the counter or transmitter value. |
| Too many pulses during one tip | Review contact filtering, loose wiring and the counter input. Check that one event is not being counted or uploaded twice. |
| Persistent difference after cleaning | Recheck level and repeat the prescribed controlled-water test. Do not compensate for an uncertain mechanical condition by changing the software increment. |
| Discontinuity after restart | Check reset behavior, retained totals, time boundary and duplicate-data handling before interpreting the result as a weather event. |
Inspect the aperture, funnel, insect screen where fitted, tipping mechanism, level and cable. Remove debris without changing bucket adjustment. After cleaning or relocation, repeat a controlled test and note the maintenance time so a sudden change in the rainfall series can be explained.
The 0 to 50 degrees C operating range is distinct from the -40 to 80 degrees C storage range. Storage tolerance does not authorize operation in freezing weather. Snow and ice need a suitable precipitation instrument and operating method; adding an unapproved heater is not a substitute for selecting that instrument.

It reports completed bucket increments, so the first tip can occur after the first drops. Use the required timing and accumulation resolution to decide whether this behavior is acceptable. Do not treat a no-tip interval as proof of a completely dry interval.
A compatible PLC counter can read the reed-switch version when its input and filtering suit the signal. Confirm the wiring and supply arrangement of that version. A general analog input cannot read contact closures as rainfall without the appropriate receiving function.
Only if the collector remains level, accessible and free of interference from crossarms, other instruments and nearby surfaces. If those conditions cannot be met, use a separate base and include its cable route in the station scope.
No. The specification names an indoor test rate. The installation and collection environment introduce additional effects. Compare the expected intensity and exposure with the stated operating conditions rather than applying the laboratory figure to all weather.
Provide the existing increment, output, supply, cable length and logger input, plus mounting details. State whether the requirement is the instrument alone or also foundations, surge protection and commissioning. Ask how the replacement total should enter the existing historical record.
Use local dust, leaf fall, insects and birds to set inspection frequency, then adjust it from observed fouling. Inspect after a suspect event and after severe weather. Cleaning is complete only when the catch is clear, the mechanism moves normally and an appropriate response check has passed.
Select this industrial rain gauge when its liquid-precipitation range, 0.2 mm increment and available outputs match the required record. Include exposure, counting and restart checks in acceptance. For a NiuBoL quotation, send the required output and logger details together with the proposed collecting position and expected rainfall conditions.
Sensors & Weather Stations Catalog
Agriculture Sensors and Weather Stations Catalog-NiuBoL.pdf
Weather Stations Catalog-NiuBoL.pdf
Agriculture Sensors Catalog-NiuBoL.pdf
Water Quality Sensor Catalog-NiuBoL.pdf
Related recommendations
Multi-Depth Soil Sensor RS485
TDR Soil Moisture Sensor
Pyranometer Solar Radiation Sensors
Soil ph sensor
Tipping Bucket Rain Gauge - ABS and Stainless Steel
Air Temperature and Humidity Sensor
Screenshot, WhatsApp to identify the QR code
WhatsApp number:+8615367865107
(Click on WhatsApp to copy and add friends)