Call Phone +8618073152920 Hotline: +8618073152920
Call Phone +8618073152920
English
CONTACT US/ CONTACT US
Consumer hotline +8618073152920
Changsha Zoko Link Technology Co., Ltd.

Email:Arvin@niubol.com

WhatsApp:+8615367865107

Address:Room 102, District D, Houhu Industrial Park, Yuelu District, Changsha City, Hunan Province, China

Position:Home >> Download >> All products

All products

Outdoor Noise Monitoring Sensor | NBL-W-NS

Outdoor Noise Monitoring Sensor | NBL-W-NS

Our outdoor noise sensor is a professional, high-performance device designed for precise measurement of environmental sound. It meets the IEC 61672 Type 2 standard, is durable and suitable for long-term outdoor use. The sensor employs a high-performance capacitive microphone and internationally recognized frequency-weighting technology, enabling accurate detection of noise levels from 30 to 130 decibels, meeting diverse monitoring needs. Its IP65 protection grade ensures reli···

Inquiry

Tel/WhatsApp:+8615367865107

Email:Arvin@niubol.com +Nearly 100 partner companies in more than 75 countries. We are committed to providing high-quality, practical products to meet your needs and help you solve problems. Our products comply with international standards and are certified with ISO, CE and RoHS.

Product Details

NBL-W-NS Outdoor Noise Monitoring Sensor

The NiuBoL NBL-W-NS Outdoor Noise Sensor is designed for fixed environmental sound-level monitoring at construction sites, industrial facilities, roads, public areas and environmental monitoring stations.

It uses a 0.5-inch condenser microphone to measure sound levels within a specified range of 30–130 dB and a frequency range of 31.5 Hz to 8 kHz. A fast response time of 200 ms enables the sensor to provide regularly updated measurements to compatible acquisition equipment.

The NBL-W-NS operates from DC 12V and is available with RS485 Modbus RTU or optional 4–20mA output configurations. Its published IP65 enclosure rating supports appropriate outdoor installations, while the microphone, windscreen, cable connections and mounting position require suitable protection and maintenance.

This is a fixed noise-level measuring sensor, not a complete regulatory noise-monitoring station. Data logging, remote communication, noise-limit alarms and formal compliance reporting require separately selected equipment and validated measurement procedures.

NiuBoL NBL-W-NS outdoor noise monitoring sensor with condenser microphone windscreen and connection cable

Select the NBL-W-NS for Fixed Noise Monitoring

The NBL-W-NS is intended for monitoring locations where an electrical noise-level signal must be collected by an external device over time.

Its main product characteristics include:

  • 30–130 dB measuring range: Environmental sound-level measurement for suitable outdoor and industrial monitoring applications.

  • 0.5-inch condenser microphone: Converts acoustic pressure variations into electrical signals.

  • 31.5 Hz–8 kHz frequency range: Specified acoustic frequency response range.

  • 200 ms fast response: Supports monitoring of changes in environmental noise levels.

  • RS485 Modbus RTU: Digital measurement transmission to compatible PLCs, RTUs and data loggers.

  • Optional 4–20mA: Analog configuration for compatible industrial monitoring equipment.

  • DC 12V operation: Suitable for integration with a properly designed monitoring power supply.

  • Protective microphone windscreen: Helps reduce direct wind effects on the microphone during suitable outdoor measurements.

When ordering, select the required signal output and confirm whether the project needs basic instantaneous noise readings or additional acoustic indicators such as equivalent continuous sound level (LAeq).

NBL-W-NS Outdoor Noise Sensor Technical Specifications

ParameterSpecification
ModelNBL-W-NS
Product TypeOutdoor Environmental Noise Sensor
Measured ParameterSound / Noise Level
Measurement Range30–130 dB
Frequency Range31.5 Hz–8 kHz
Time ResponseFast, T = 200 ms
Microphone TypeCondenser Microphone
Microphone Size0.5 inch
Frequency-Weighting ReferenceIEC 61672 Type 2 Characteristics under Specified Conditions
Calibration Reference94 dB Reference Signal; B&K Type 4226 Calibrator Referenced
Power SupplyDC 12V
Digital OutputRS485 Modbus RTU
Optional Analog Output4–20mA, According to Ordered Version
Default Baud Rate9600 bps
Minimum Polling Interval1000 ms
Power ConsumptionApproximately 20 mW at DC 12V
Maximum Output Impedance200Ω
Operating Temperature−15 to +50°C
Operating Relative HumidityBelow 80%RH
Published Protection RatingIP65
HousingABS Plastic Housing

The acoustic reference listed above describes a specified frequency-weighting characteristic and calibration reference. Independent certification of the complete instrument to IEC 61672 Class 2 has not been established by these specifications.

For regulated acoustic monitoring projects, confirm the required weighting, time-averaging indicators, calibration documentation and applicable instrument standard before ordering.

Microphone Construction and Installation Dimensions

The NBL-W-NS has a slim cylindrical body with a microphone sensing section and protective windscreen.

The original mechanical drawing shows an overall length of approximately 280 mm, a windscreen diameter of approximately 80 mm and body diameter sections of approximately 30 mm and 22 mm.

The drawing also identifies an M22 mounting interface.

These dimensions are useful when selecting a suitable bracket or monitoring mast. Confirm the actual supplied mechanical version before preparing custom mounting hardware.

NBL-W-NS noise sensor dimension drawing showing 280 mm overall length microphone windscreen and cylindrical mounting body

Outdoor Noise Monitoring Applications

The NBL-W-NS is designed to provide sound-level measurements as part of a larger environmental monitoring installation.

Construction Site Noise Monitoring

Construction projects can collect noise-level measurements at selected boundary or monitoring locations.

The readings may be used to observe changes in site noise and support environmental management activities. Formal compliance reporting requires the appropriate measurement indicators and procedures.

Urban and Road Traffic Monitoring

Fixed outdoor sensors can provide sound-level information at selected roadside, urban or public-space locations.

A compatible data logger can store the readings and allow operators to compare different monitoring periods.

Industrial Environmental Monitoring

The sensor can provide noise data at selected industrial monitoring points, including locations near machinery, workshops and plant boundaries.

For occupational exposure assessment or regulated industrial noise measurements, an instrument and measurement method appropriate to the applicable requirements should be selected.

Parks, Campuses and Public Facilities

Outdoor noise sensors can help observe environmental sound conditions around public facilities and sensitive monitoring locations.

Sensor position and surrounding reflective surfaces should be considered when interpreting the measurements.

Outdoor Noise Monitoring System Configuration

The NBL-W-NS is a measurement component. A complete monitoring station may combine the noise sensor with a suitable data logger, outdoor enclosure, communications equipment, mounting structure and power supply.

NBL-W-NS Noise Sensor → RS485 / 4–20mA Input → Data Logger or PLC → Optional Network Gateway → Monitoring Software

Depending on the project, an environmental monitoring station may also collect particulate matter, wind speed, wind direction, temperature or humidity measurements from additional sensors.

External data acquisition and communication equipment must be selected for the required number of inputs, network method and data collection interval.

Example of outdoor environmental noise and dust monitoring station with microphone windscreen weather sensors and LED display

RS485 Modbus RTU Data Acquisition

The RS485 version of the NBL-W-NS supports Modbus RTU communication for compatible industrial controllers and environmental monitoring equipment.

Communication Settings

ParameterSetting
Communication InterfaceRS485
Communication ProtocolModbus RTU
Default Baud Rate9600 bps
Data Bits8
ParityNone
Stop Bits1 or 2, According to Configuration
Read Function03
Noise RegisterStarting Address 0000; One Register

The receiving equipment should read the documented noise register, interpret the returned data according to the selected sensor configuration and store the values with suitable timestamps.

RS485 Wiring

Wire ColorFunction
RedPower Positive
Black / GreenPower Negative
YellowRS485 A (+)
BlueRS485 B (−)

Disconnect power before wiring. The cable identification supplied with the ordered instrument should be used if it differs from this standard arrangement.

Optional 4–20mA Output

A 4–20mA version is also listed for use with compatible industrial analog input equipment.

The analog current configuration, measurement scaling and corresponding wiring should be confirmed before ordering. RS485 and 4–20mA are alternative signal configurations.

Outdoor Noise Sensor.jpg

Outdoor Installation and Measurement Considerations

Install the sensor at a location representative of the noise source or environmental area being monitored.

Acoustic exposure: Avoid unintended shielding or excessive reflections from nearby walls and equipment unless those conditions form part of the monitoring objective.

Microphone windscreen: Keep the windscreen properly fitted, clean and in good condition. Wind-related noise can affect outdoor acoustic measurements.

Mechanical vibration: Avoid mounting directly on machinery or structures transmitting strong vibration to the microphone assembly.

Weather exposure: Provide suitable protection for external cable joints and connectors. Check the specified temperature and humidity limits of the instrument.

Maintenance: Inspect the microphone protection, cable and mounting structure periodically. Do not use sharp objects, aggressive solvents or corrosive liquids on the microphone assembly.

Acoustic Indicators and Compliance Requirements

The NBL-W-NS provides a noise-level measurement signal suitable for integration into compatible monitoring systems.

Some environmental monitoring projects require additional acoustic quantities, such as:

  • Equivalent continuous sound level (LAeq).

  • Maximum and minimum sound levels (Lmax and Lmin).

  • Statistical noise indicators (L10, L50 and L90).

  • Specified frequency weighting and time weighting.

  • Calibration traceability and defined measurement uncertainty.

These functions should not be assumed to be independently available from the standard NBL-W-NS measurement register.

For statutory environmental noise monitoring, workplace exposure assessment or other regulated applications, the instrument class, acoustic indicators and calibration documentation must be verified against the applicable project requirements.

Product Handling and Inspection

Before installation, inspect the supplied microphone, windscreen, body, cable and connector for damage.

Confirm the selected output interface and verify that the instrument is operating within the required supply and environmental limits.

The microphone is a sensitive measuring component and should not be dismantled or mechanically altered during normal installation.

NBL-W-NS noise sensor microphone shown during product handling and inspection

Outdoor Noise Sensor Ordering Checklist

For a suitable quotation, please confirm the following requirements:

  • Application: Construction site, road traffic, industrial environment, public facility or another monitoring location.

  • Acoustic requirements: Standard noise-level output or additional acoustic indicators.

  • Output: RS485 Modbus RTU or 4–20mA.

  • Installation: Mounting method, cable length and environmental exposure.

  • System integration: PLC, RTU, data logger or other receiving equipment.

  • Documentation: Any required calibration certificate, instrument-class evidence or regulatory compliance documentation.

  • Order details: Quantity and destination country.

NBL-W-NS Noise Sensor PDF Download

Download the NBL-W-NS instruction manual for the RS485 configuration, including product specifications, wiring, dimensions and Modbus RTU communication information.

PDFNBL-W-NS Noise-Sensor-Instruction-Manual.pdf

NBL-W-NS Noise Monitoring Sensor Selection and Quotation

The NiuBoL NBL-W-NS is designed for fixed noise-level measurement in environmental and industrial monitoring systems. Its RS485 Modbus RTU interface, optional 4–20mA configuration and DC 12V power supply allow integration with compatible external data acquisition equipment.

For other model details, see the NBL-W-NS Environmental Noise Sensor.

To request technical information or pricing, contact NiuBoL with your application and measurement requirements.

Sensors & Weather Stations Catalog

Agriculture Sensors and Weather Stations Catalog-NiuBoL.pdf

Weather Stations Catalog-NiuBoL.pdf

Agriculture Sensors Catalog-NiuBoL.pdf

Water Quality Sensor Catalog-NiuBoL.pdf

Related recommendations

Tell us your requirements,Let's discuss more about your project,we can do more.

Name*

Tel*

Email*

Company*

Country*

Message


online
Contacts
Email
Top
XOutdoor Noise Monitoring Sensor | NBL-W-NS-All products-Automatic Weather Stations_Industrial, Agricultural, Water & Environmental IoT Monitoring Solutions—NiuBoL

Screenshot, WhatsApp to identify the QR code

WhatsApp number:+8615367865107

(Click on WhatsApp to copy and add friends)

Open WhatsApp

The WhatsApp ID has been copied, please open WhatsApp to add consultation details!
WhatsApp