Call Phone +8618073152920 Hotline: +8618073152920
Call Phone +8618073152920
English
CONTACT US/ CONTACT US
Consumer hotline +8618073152920
Changsha Zoko Link Technology Co., Ltd.

Email:Arvin@niubol.com

WhatsApp:+8615367865107

Address:Room 102, District D, Houhu Industrial Park, Yuelu District, Changsha City, Hunan Province, China

Position:Home >> Download >> All products

All products

NBL-S-THR Irrigation Soil Sensor with RS485 Output

NBL-S-THR Irrigation Soil Sensor with RS485 Output

Integrate the NiuBoL NBL-S-THR irrigation soil sensor with your controller. Check probe placement, wetting delays and RS485 data before requesting a project quotation.

Inquiry

Tel/WhatsApp:+8615367865107

Email:Arvin@niubol.com +Nearly 100 partner companies in more than 75 countries. We are committed to providing high-quality, practical products to meet your needs and help you solve problems. Our products comply with international standards and are certified with ISO, CE and RoHS.

Product Details

Quick Answer: The NiuBoL NBL-S-THR irrigation soil sensor supplies soil moisture and temperature measurements to a controller or data logger. It measures 0-100% soil moisture and -50 to 100 degrees C, with RS485 Modbus RTU, 4-20mA or 0-5V output options. Choose it as feedback from a defined root-zone point; the controller must still manage valves, wetting delay, runtime limits and missing measurements.

NiuBoL NBL-S-THR cylindrical soil temperature and moisture probe for irrigation monitoring

NBL-S-THR electrical and measurement specifications

ParameterSpecification
Soil moisture0-100%; 0.1% resolution; +/-3% specified accuracy
Soil temperature-50 to 100 degrees C; 0.1 degree C resolution; +/-0.5 degree C accuracy
Supply12-24 VDC
Digital optionRS485 Modbus RTU
Current-output option4-20mA; receiving load no more than 250 ohms
Voltage-output option0-5V; receiving load at least 1 kohm
PowerApproximately 0.3 W
Operating environment-40 to 80 degrees C
Sensor protectionIP68

The moisture percentage is a soil-water measurement derived from dielectric response, not air relative humidity and not the percentage of plant-available water remaining. The temperature measurement span is also not permission to operate the complete assembly outside its -40 to 80 degrees C environmental limit.

Place the feedback point inside the zone the valve actually waters

Divide the site by valve zone, soil type, slope and crop condition. Within each zone, avoid anomalous depressions, leaks, wheel tracks and field edges unless those are the subject of monitoring. More than one depth helps distinguish shallow wetting from water that reaches the active roots or drains below them.

For drip irrigation, record distance from the emitter as well as depth. A point immediately under an emitter detects a different part of the wetted volume from a point near its edge. Choose the location from the root-zone question rather than where the cable is easiest to bury.

The measurement responds to the soil's apparent dielectric properties. Air gaps around the probe behave very differently from moist soil. Insert the sensing area into undisturbed soil where possible, or repack carefully at the original density. Soil salinity, texture and bulk density can affect how a raw reading relates to laboratory water content, so local comparison remains valuable.

In an orchard, compare emitter output and soil conditions before assuming one representative tree describes every row. In a greenhouse bed, short pulses can wet a shallow point without reaching a deeper root layer. In a remote field, choose a point that the operator can inspect and the local controller can continue to evaluate if the uplink is unavailable.

Record cultivation and cable routes so later field work does not displace the point. Sensor sealing does not protect an unsealed cable joint or prevent damage from tools. Confirm cable length, termination and burial protection for the installation instead of treating IP68 as a rating for every field connection.

Observe wetting delay before enabling moisture-based control

Record the dry baseline, start one known irrigation cycle and observe the time to response, peak and redistribution. Compare the trend with manual soil inspection and emitter flow. Acceptance is not just communication success; the probe must respond at a time and magnitude consistent with its physical location.

Begin with supervised operation. Confirm the selected valve feeds the monitored area and that water actually leaves the emitters. Record valve start, duration and the moisture response at each depth, including redistribution after the valve closes. The first response time is a site observation, not a fixed sensor delay to copy between soil types.

A sensor outside the wetted volume can remain dry while the system applies water elsewhere. A point close to an emitter can rise quickly while the wider root zone remains less wet. Neither trace, on its own, establishes the applied irrigation volume. Use emitter or flow information when water quantity is part of the control decision.

If the reading does not rise, do not extend watering indefinitely. Check valve operation, flow, probe contact and location. A plugged emitter, misplaced probe and failed sensor require different actions, even though each can produce a flat moisture trace.

Use separate start, stop and abnormal-condition rules

A single on/off threshold can cause rapid valve cycling. Use separate start and stop conditions, minimum run time and a delay for water to move from the emitter to the probe. Retain manual override and high-flow or leak protection. The controller should define what happens when data is missing, stale or outside a plausible range.

Observed conditionController action to define and test
Valid moisture below the locally validated start conditionPermit a watering request only within the operating schedule and other hydraulic interlocks.
Watering starts but the probe has not responded yetAllow the observed wetting delay while retaining a bounded runtime; do not evaluate every new sample as a demand for more water.
Stop condition or maximum runtime reachedClose the valve and review redistribution before allowing the next cycle under the agreed control method.
Invalid, stale or disconnected sensorUse the agreed fallback or operator response; do not interpret missing data as extremely dry soil.

Establish the start and stop conditions from the crop, soil and measured response. A 30% reading does not imply the same water availability in every soil. Validate one hydraulic zone before applying its settings elsewhere, and repeat the review after a changed emitter layout, crop or monitoring depth.

Keep valve control local when the project requires operation during a communications outage. The remote platform can provide supervision, but loss of the uplink should not leave a valve waiting indefinitely for a server command. Sensor validity, valve runtime and the intended fallback belong in the controller's tested logic.

Environmental monitoring system diagram with sensor acquisition and remote transmission

Verify two channels and the ordered electrical version

The NBL-S-THR V4.0 sensor uses 9600 baud, 8 data bits and no parity, with more than 1000 ms between RS485 communications. Match the delivered stop-bit setting and channel map. Temperature and moisture are separate values, not one interchangeable register.

In the V4.0 configuration, both channels have 0.1-unit conversion and 0x7FFF denotes invalid or missing data. Check the supplied firmware and recognize the invalid state before scaling. For example, a valid moisture count of 272 corresponds to 27.2%; it is not a genuine dry-soil value if the communication has failed and the controller has substituted zero.

For analog acquisition, the documented moisture conversion is (I - 4) / 16 x 100%, with I in mA. The temperature conversion for the -50 to 100 degrees C span is (I - 4) / 16 x 150 - 50. At 12 mA, the moisture channel represents 50% while the temperature channel represents 25 degrees C. Verify the separate inputs and the ordered wiring rather than using one generic percentage conversion.

The V4.0 current-output calculation is for the specified three-wire arrangement. Do not assume a loop-powered two-wire connection, and check the 250-ohm load limit against the receiving equipment. For RS485, bench-test each probe and assign distinct supported addresses before connecting the field bus.

A compatible logger or gateway can store and transmit the readings. Define how the controller recognizes old timestamps or failed polling independently of whether the dashboard remains reachable. Network availability and a valid new root-zone measurement are different conditions.

Add EC only when the irrigation decision needs conductivity

NBL-S-THR provides temperature and moisture, not conductivity or fertilizer concentration. If the project also needs a conductivity trend, review the NBL-S-TMC three-channel probe and its interpretation requirements. EC still needs moisture and method context; it is not a direct nutrient-dose command.

Select the channel set from the intended control or investigation. Additional measurements are useful when someone will interpret and maintain them, not simply because more numbers can be shown on the same dashboard. The alternative probe below is a different assembly from the NBL-S-THR illustrated at the start.

Alternative NBL-S-TMC rectangular soil probe with temperature moisture and EC channels

Project Decision FAQ

Q1. Can the irrigation soil sensor energize a valve directly?

No. It provides measurements through the selected interface. A controller and suitable valve output stage apply the operating rules and switch the hydraulic equipment. Include that hardware and logic when requesting an automated system.

Q2. Can one probe control several valve zones?

Only if a project-specific assessment supports that arrangement. Different soils, emitters, crops and slopes can produce different drying and wetting patterns. A sensor in one zone cannot directly confirm water delivery in another independently operated zone.

Q3. Why does moisture remain low after watering starts?

Check actual valve and emitter flow, the wetting delay to the chosen depth and whether the point is inside the wetted volume. Then inspect soil contact and the electrical channel. Do not keep increasing runtime before distinguishing hydraulic and measurement causes.

Q4. Does IP68 cover a buried field-made splice?

Not automatically. The sensor's enclosure rating does not establish a splice's sealing or mechanical protection. Specify suitable connections and strain relief separately and inspect exposed transitions during maintenance.

Q5. What should the controller do with 0x7FFF?

For the V4.0 protocol, identify 0x7FFF as invalid or missing before numerical conversion. Apply the defined fallback, alarm or inhibited action and confirm recovery using the supplied firmware. Do not display it as an extreme valid moisture or temperature.

Q6. Can the same moisture threshold be used in clay and sandy soil?

Not without validation. Soil properties and root-zone management determine what a measured percentage means for the crop. Establish thresholds using the appropriate agronomic method and supervised field response, then retain hysteresis and runtime limits.

Q7. What should a controller-integration inquiry include?

Provide valve zones, soil and crop, probe depths and emitter positions, controller model, input type and cable routes. State requirements for local control, remote supervision and failure handling. NiuBoL can then review the sensor version and acquisition scope against the actual irrigation layout.

Summary

Use NBL-S-THR as temperature and moisture feedback from a defined irrigated zone. Verify placement and wetting response before enabling bounded valve logic, then check both channels at the controller. Send NiuBoL the zone layout and receiving interface to review the appropriate configuration.

Sensors & Weather Stations Catalog

Agriculture Sensors and Weather Stations Catalog-NiuBoL.pdf

Weather Stations Catalog-NiuBoL.pdf

Agriculture Sensors Catalog-NiuBoL.pdf

Water Quality Sensor Catalog-NiuBoL.pdf

Related recommendations

Tell us your requirements,Let's discuss more about your project,we can do more.

Name*

Tel*

Email*

Company*

Country*

Message


online
Contacts
Email
Top
XNBL-S-THR Irrigation Soil Sensor with RS485 Output-All products-Automatic Weather Stations_Industrial, Agricultural, Water & Environmental IoT Monitoring Solutions—NiuBoL

Screenshot, WhatsApp to identify the QR code

WhatsApp number:+8615367865107

(Click on WhatsApp to copy and add friends)

Open WhatsApp

The WhatsApp ID has been copied, please open WhatsApp to add consultation details!
WhatsApp