Illuminance Lux Sensor 0–200,000 Lux | RS485 | NBL-W-LUX

Illuminance Lux Sensor 0–200,000 Lux | RS485 | NBL-W-LUX

The Illuminance Lux Sensor Transmitter is a high-performance light intensity measurement device that uses a highly sensitive silicon blue photovoltaic detector as the core sensor. This product features a wide measurement range, excellent linearity, good waterproof performance, easy installation, and supports long-distance transmission. Users can select the appropriate range and output method according to different application scenarios. It is widely used in agricultural green···

Inquiry

Tel/WhatsApp:+8615367865107

Email:Arvin@niubol.com +Nearly 100 partner companies in more than 75 countries. We are committed to providing high-quality, practical products to meet your needs and help you solve problems. Our products comply with international standards and are certified with ISO, CE and RoHS.

Product Details

The NiuBoL NBL-W-LUX Illuminance Lux Sensor is designed to measure environmental illuminance in lux for agricultural greenhouses, building automation, urban lighting, environmental monitoring and industrial data acquisition applications.

The sensor uses a silicon blue photovoltaic detector to convert incident light into an electrical measurement signal. It offers a measurement range of 0–200,000 lux, a spectral response of 380–730 nm and a specified measurement accuracy of ±7%.

Available with RS485 Modbus RTU, 4–20 mA or 0–5 V output, the NBL-W-LUX can be integrated with compatible PLCs, data loggers, RTUs and environmental monitoring systems.

NBL-W-LUX illuminance lux sensor for greenhouse and industrial light monitoring

NBL-W-LUX Illuminance Sensor Features

  • Wide Measurement Range: Measures illuminance from 0 to 200,000 lux for indoor and outdoor light monitoring applications.

  • Photovoltaic Detection: Uses a silicon blue photovoltaic detector with a specified spectral response of 380–730 nm.

  • Multiple Output Options: Available with RS485 Modbus RTU, 4–20 mA or 0–5 V output configurations.

  • Industrial Power Supply: DC 12 V or DC 24 V power supply configurations for compatible acquisition systems.

  • Simple Installation: Two mounting holes allow installation using M4 screws and suitable mounting brackets.

  • Flexible Cable Configuration: Standard 2.5 m cable, with alternative lengths available according to order requirements.

  • System Integration: Suitable for integration with compatible industrial controllers, weather stations and agricultural monitoring equipment.

NBL-W-LUX Illuminance Lux Sensor Technical Specifications

ParameterSpecification
ModelNBL-W-LUX
Product TypeIlluminance Sensor / Lux Transmitter
DetectorSilicon Blue Photovoltaic Detector
Measurement ParameterIlluminance (lux)
Measurement Range0–200,000 lux
Spectral Range380–730 nm
Specified Accuracy±7%
Power SupplyDC 12 V or DC 24 V, According to Ordered Configuration
Output OptionsRS485 / 4–20 mA / 0–5 V
Digital Communication ProtocolModbus RTU (RS485 Version)
Baud Rate9600 bps
Communication Interval≥1000 ms
Load ResistanceVoltage Output: ≥1 kΩ
Current Output: ≤300 Ω
Operating Temperature−10 to +70 °C
Operating Relative Humidity0–80% RH
Standard Cable Length2.5 m
Product Weight170 g

Configuration Note: RS485, 4–20 mA and 0–5 V are selectable output configurations. Confirm the required measurement range, supply voltage, signal type and cable length before ordering. For applications requiring a specific ingress protection rating or defined measurement uncertainty, confirm the applicable specifications separately.

How Does an Illuminance Lux Sensor Work?

An illuminance sensor detects incident optical radiation and converts the detector response into an electrical signal representing illuminance.

Illuminance describes the luminous flux incident on a surface per unit area. Its measurement unit is lux (lx), equivalent to one lumen per square meter.

The NBL-W-LUX uses a photovoltaic sensing element and signal-processing circuitry to provide an output corresponding to the selected illuminance measurement range.

Measurement performance can be influenced by the spectral characteristics of the light source, sensor orientation, contamination of the optical surface and the measurement environment.

Illuminance, Solar Radiation and PAR: What Is the Difference?

Although illuminance sensors, solar radiation sensors and plant-light instruments all respond to optical radiation, they measure different physical quantities.

InstrumentMeasurement UnitPrimary Application
Illuminance Sensorlux (lx)General Light Environment Monitoring
PyranometerW/m²Solar Irradiance and Environmental Energy Measurements
PAR-Band Irradiance SensorW/m²Irradiance Within the Photosynthetically Active Spectral Band
Quantum Sensorμmol/(m²·s)Photosynthetic Photon Flux Density (PPFD)

The NBL-W-LUX is an illuminance instrument. It does not directly measure broadband solar irradiance, photosynthetic photon flux density or daily light integral (DLI).

Lux measurements can support greenhouse light-condition monitoring, particularly when comparing similar lighting environments. However, illuminance is weighted according to human visual sensitivity and is not directly equivalent to the photon flux available for plant photosynthesis.

For crop-lighting research or supplementary lighting systems that require PPFD or DLI, select an appropriate quantum measurement instrument.

NiuBoL industrial illuminance sensors for light environment monitoring

Illuminance Lux Sensor Wiring and Output Options

The NBL-W-LUX can be supplied with different electrical outputs to match the receiving controller or acquisition equipment.

When using a compatible NiuBoL collector, connect the sensor to the designated input according to the supplied wiring instructions.

For independent system integration, the documented cable identification is shown below.

Wire Color0–5 V Version4–20 mA VersionRS485 Version
RedPower PositivePower PositivePower Positive
Black (Green)Power GroundSee Ordered Wiring DiagramPower Ground
YellowVoltage SignalCurrent SignalA+ / TX
Blue——B− / RX

Wiring Note: Confirm the actual output configuration and supplied connection diagram before applying power. The analog current-loop arrangement must match the delivered transmitter and receiving input. Do not assume that all output versions use the same wiring method.

Analog Output Conversion Formulas

For analog-output versions, the receiving controller converts the electrical signal into the corresponding illuminance value using the configured measurement range.

4–20 mA Illuminance Sensor

L = (I − 4) / 16 × Lmax

  • L = measured illuminance (lux).

  • I = measured current (mA).

  • Lmax = upper limit of the selected zero-based measurement range (lux).

0–5 V Illuminance Sensor

L = V / 5 × Lmax

  • L = measured illuminance (lux).

  • V = measured output voltage (V).

  • Lmax = upper limit of the selected zero-based measurement range (lux).

For a 0–200,000 lux configuration, the corresponding ideal analog scaling values are:

IlluminanceCurrent OutputVoltage Output
0 lux4 mA0 V
50,000 lux8 mA1.25 V
100,000 lux12 mA2.5 V
150,000 lux16 mA3.75 V
200,000 lux20 mA5 V

These values illustrate the nominal electrical scaling and do not represent independently measured calibration results. Configure the receiving system according to the actual ordered measurement range.

RS485 Modbus RTU Illuminance Sensor Integration

The RS485 version of the NBL-W-LUX supports Modbus RTU communication for integration with compatible PLCs, RTUs and industrial data acquisition equipment.

Communication ParameterSpecification
InterfaceRS485
ProtocolModbus RTU
Baud Rate9600 bps
Data Bits8 Bits
ParityNone
Stop Bits1 or 2 Bits, Confirm Device Configuration
Minimum Communication Interval1000 ms

Before integration, confirm the device address, serial settings, register definitions, data format and illuminance scaling factor for the delivered sensor.

For multiple sensors sharing an RS485 network, use compatible communication settings and unique device addresses.

The sensor itself does not provide independent wireless communication. A compatible data acquisition device or IoT gateway is required for remote data transmission.

Illuminance Sensor Installation Instructions

1. Select a Representative Measurement Location

Choose the mounting location according to the surface or environment whose illuminance must be monitored.

Avoid unintended shading from mounting poles, nearby equipment or structures unless the shaded condition is part of the intended measurement.

2. Install the Sensor

Fix the sensor to a suitable bracket using M4 screws and nuts through its two mounting holes.

Maintain the required observation orientation. For horizontal illuminance monitoring, install the sensing surface in the intended horizontal measurement plane.

3. Connect Power and Signal Cables

Disconnect power before wiring. Connect the supply and signal conductors according to the selected output configuration, then verify the connections before switching on the equipment.

4. Verify Measurement and Data Scaling

Check the sensor response under different light conditions and confirm that the receiving system displays the expected measurement units and scaling.

A functional light-response test does not establish calibrated measurement accuracy. Where numerical accuracy is critical, use an appropriate reference instrument and controlled comparison procedure.

Illuminance Lux Sensor Applications

Agricultural Greenhouses

Monitor changes in the greenhouse light environment, shading conditions and supplementary lighting operation.

Illuminance measurements can provide useful environmental information but should not be treated as direct measurements of photosynthesis, PPFD or crop productivity.

Smart Buildings and Lighting Automation

Provide ambient light measurements for building monitoring, lighting management and compatible automatic lighting control systems.

Automatic adjustment of lighting equipment requires an external controller and appropriate control hardware.

Urban Lighting and Infrastructure

Monitor environmental illumination for lighting studies, infrastructure management and integration with compatible street-lighting control systems.

Meteorological and Environmental Monitoring

Record local illuminance changes associated with daylight, cloud cover and surrounding environmental conditions.

For solar energy measurements expressed in W/m², use an appropriate solar radiation instrument instead of a lux sensor.

Industrial Monitoring and Research

Provide illuminance measurements for industrial environments, laboratories and general environmental observation projects, subject to the required measurement accuracy and applicable operating conditions.

NiuBoL illuminance sensor configurations for environmental and industrial monitoring

Illuminance Sensor Maintenance and Troubleshooting

Regular inspection helps maintain representative optical measurements and reliable electrical connections.

Observed ProblemPossible CauseRecommended Check
Reading Is Unexpectedly LowDust, Deposits or Unintended ShadingInspect and Clean the Optical Surface
Analog Reading Is IncorrectIncorrect Input Range or ScalingVerify Signal Type and Ordered Measurement Range
No RS485 ResponsePower, Wiring or Communication ConfigurationCheck Supply, A/B Wiring, Device Address and Serial Settings
Reading Remains at MaximumPossible Over-Range Condition or Signal Processing IssueCheck Light Conditions and Receiving-System Configuration

Do not disassemble the sensor or clean the optical surface with sharp objects or corrosive liquids. Contact the manufacturer before modifying factory-installed cables or internal components.

NBL-W-LUX Illuminance Sensor Ordering Information

Specify the following information when ordering an illuminance sensor:

  • Product Model: NBL-W-LUX.

  • Measurement Range: Standard 0–200,000 lux, or another confirmed configuration.

  • Power Supply: DC 12 V or DC 24 V.

  • Output: RS485, 4–20 mA or 0–5 V.

  • Cable Length: Standard 2.5 m or customized length.

  • Installation Environment: Indoor, greenhouse or appropriately protected outdoor installation.

  • Receiving Equipment: PLC, data logger, RTU or other compatible acquisition device.

Frequently Asked Questions (FAQ)

Q1. What does an illuminance lux sensor measure?

An illuminance sensor measures illuminance, expressed in lux. It describes the light incident on a surface according to a photometric measurement scale.

Q2. What is the measurement range of the NBL-W-LUX?

The standard specified measurement range is 0–200,000 lux, with a spectral response range of 380–730 nm and specified accuracy of ±7%.

Q3. Can the NBL-W-LUX measure PAR or PPFD?

No. The NBL-W-LUX measures illuminance in lux. PAR-band irradiance and PPFD require instruments designed and calibrated for those quantities.

Q4. Does the illuminance sensor support RS485 Modbus RTU?

Yes. The RS485 version supports Modbus RTU communication for compatible PLCs, RTUs, data loggers and industrial monitoring systems.

Q5. Are RS485 and analog outputs available simultaneously?

The NBL-W-LUX is offered with selectable output configurations. Confirm the required signal type when ordering rather than assuming all outputs are provided simultaneously.

Q6. Can the NBL-W-LUX be used outdoors?

The sensor can be considered for outdoor light-monitoring applications when its operating conditions and installation protection are suitable. Confirm humidity exposure, ingress protection requirements and cable arrangements before deployment.

Q7. Can this sensor automatically control greenhouse lighting?

The sensor provides illuminance measurements. Automatic lighting control requires a compatible controller, configured control logic and suitable electrical switching equipment.

NiuBoL Illuminance Sensor and Environmental Monitoring Solutions

NiuBoL supplies illuminance sensors, solar radiation instruments, agricultural sensors and compatible data acquisition equipment for environmental monitoring and industrial system integration.

For product selection, specify the required measurement quantity, signal interface, installation environment and receiving equipment.

Contact NiuBoL for NBL-W-LUX illuminance sensor specifications, technical support and a project-specific quotation.

NBL-W-LUX Illuminance Lux Sensor Data Sheet and Instruction Manual

Download the instruction manual for technical specifications, installation information, analog output conversion formulas, wiring and RS485 communication details.

PDFIllumination-sensor.pdf

Sensors & Weather Stations Catalog

Agriculture Sensors and Weather Stations Catalog-NiuBoL.pdf

Weather Stations Catalog-NiuBoL.pdf

Agriculture Sensors Catalog-NiuBoL.pdf

Water Quality Sensor Catalog-NiuBoL.pdf

Related recommendations

Tell us your requirements,Let's discuss more about your project,we can do more.

Name*

Tel*

Email*

Company*

Country*

Message


online
Contacts
Email
Top
XIlluminance Lux Sensor 0–200,000 Lux | RS485 | NBL-W-LUX-All products-Automatic Weather Stations_Industrial, Agricultural, Water & Environmental IoT Monitoring Solutions—NiuBoL

Screenshot, WhatsApp to identify the QR code

WhatsApp number:+8615367865107

(Click on WhatsApp to copy and add friends)

Open WhatsApp

The WhatsApp ID has been copied, please open WhatsApp to add consultation details!
WhatsApp