In November 2026, NiuBoL delivered an NBL-S-THR TDR soil moisture and temperature sensor to an engineering-sector customer in Santiago, Chile. The supplied instrument was configured with a 4–20 mA analog output, illustrating our ability to support customers whose existing monitoring equipment uses industrial analog interfaces rather than digital communication.
Soil Monitoring in Chile
Chile's agricultural regions include vineyards, fruit orchards and irrigated farmland. Soil moisture information can help growers evaluate root-zone water conditions and plan irrigation, particularly where water availability varies seasonally.
Beyond agriculture, soil moisture and temperature measurements may support environmental research, landscape management and engineering projects requiring information about soil conditions.
NBL-S-THR TDR Soil Moisture and Temperature Sensor
The NBL-S-THR uses Time Domain Reflectometry (TDR) technology to estimate soil water content from the relationship between electromagnetic signal propagation and the dielectric properties of the surrounding soil. It also measures soil temperature.
| Parameter | Specification |
|---|---|
| Model | NBL-S-THR |
| Measurement principle | TDR |
| Soil moisture range | 0–100% |
| Soil moisture resolution | 0.1% |
| Specified soil moisture accuracy | ±3% |
| Temperature measurement range | -50°C to +100°C |
| Temperature resolution | 0.1°C |
| Specified temperature accuracy | ±0.5°C |
| Operating environment | -40°C to +80°C |
| Power supply | DC 12–24 V |
| Supplied output configuration | 4–20 mA |
| Protection rating | IP68 |
Actual soil moisture measurement performance depends on soil composition, salinity, probe contact and calibration conditions. The temperature measurement range should not be confused with the permitted operating environment.
Why Select a 4–20 mA Soil Sensor?
Many PLCs, industrial controllers and data acquisition systems accept current-loop signals. A compatible 4–20 mA soil sensor can provide measurements without requiring a Modbus implementation and can be integrated into existing analog data acquisition systems.
Before integration, customers should confirm analog channel availability, signal scaling, wiring, loop power requirements and receiving equipment compatibility for the selected version.
Potential Agricultural and Engineering Applications
In irrigation projects, soil sensors installed at representative root-zone depths can help operators observe drying trends and moisture changes following irrigation. In environmental research and engineering monitoring, soil moisture and temperature can provide additional information about local soil conditions.
Geotechnical and infrastructure safety assessments require appropriate professional instruments and validated engineering procedures; a general soil moisture sensor is not a standalone safety monitoring solution.
Sensor Selection for Different Integration Requirements
NiuBoL supplies soil moisture, temperature, electrical conductivity, pH and multi-depth soil monitoring instruments. Depending on the model, available outputs include RS485 Modbus RTU and industrial analog signals. We support individual instrument evaluations as well as larger monitoring equipment orders, helping customers choose a version that fits their measurement and integration requirements.
Looking for a TDR soil moisture sensor with an industrial analog output? Contact NiuBoL with your soil conditions, required measurements and data acquisition interface for product selection and pricing.