— Products —
WhatsApp:+8615367865107
Address:Room 102, District D, Houhu Industrial Park, Yuelu District, Changsha City, Hunan Province, China
Water Quality Sensors
NBL-ZS-206 integrated online turbidity sensor is designed and manufactured using the principle of scattered light turbidity measurement. When a beam of light is incident on a water sample, the light is scattered by the turbidity substance in the water sample, and the intensity of the scattered light in the direction perpendicular to the incident light is measured and compared with the internal calibration value to calculate the turbidity in the water sample. Degree, linearize···
Tel/WhatsApp:+8615367865107
Email:Arvin@niubol.com +Nearly 100 partner company in more than 68 countries. We are committed to providing high-quality, practical products to meet your needs and help you solve problems.Product Details
NBL-ZS-206 integrated online turbidity sensor is designed and manufactured using the principle of scattered light turbidity measurement. When a beam of light is incident on a water sample, the light is scattered by the turbidity substance in the water sample, and the intensity of the scattered light in the direction perpendicular to the incident light is measured and compared with the internal calibration value to calculate the turbidity in the water sample. Degree, linearized to output the final value. 90° angle scattered light principle, built-in temperature sensor Support RS-485, Modbus/RTU protocol Optical fiber structure, strong resistance to external light interference Infrared LED light source with high stability IP68 protection, water depth within 20 meters Convenient, fast, stable and easy to maintain.
Model | NBL-ZS-106 | |
Measuring Principle | Scattering light method | |
Measuring Range/Resolution | 0~20.00NTU | 0.01NTU/0.1℃ |
0~100.0NTU | 0.1NTU/0.1℃ | |
0~1000.0NTU | 0.1NTU/0.1℃ | |
Accuracy | ±5% or ±3NTU(0~1000.0NTU) ±3% or ±2NTU(0~100.0NTU) ±3% or ±1.5NTU(0~20.00NTU) ±0.3℃ | |
Calibration Mode | Two-point calibration | |
Temperature Compensation | Automatic temperature compensation(Pt1000) | |
Output Mode | RS-485( Modbus /RTU) and 4-20mA | |
Working Conditions | 0~50℃,<0.2MPa | |
Storage Temperature | -5~65℃ | |
Installation Mode | Immersive installation, 3/4NPT thread | |
Cable Length | 5 meters, other lengths customizable | |
Power Dissipation | 0.2W@12V | |
Source | 12~24VDC | |
Levels of Protection | IP68 | |
Sensor Shell Material | POM、ABS |
NBL-ZS-206A integrated online turbidity sensor is designed and manufactured using the principle of scattered light turbidity measurement. When a beam of light is incident on a water sample, the light is scattered by the turbidity substance in the water sample, and the intensity of the scattered light in the direction perpendicular to the incident light is measured and compared with the internal calibration value to calculate the turbidity in the water sample. Degree, linearized to output the final value.。
90° angle scattered light principle, built-in temperature sensor
Support RS-485, Modbus/RTU protocol
Optical fiber structure, strong resistance to external light interference
Infrared LED light source with high stability
IP68 protection, water depth within 20 meters
Convenient, fast, stable and easy to maintain
Installation distance requirements: keep above 5cm with side wall and above 10cm with bottom.
a)Red wire-power cord(12~24V)
b)Black wire-ground wire(GND)
c)Blue Line-485A
d)White Line-485B
After the wiring is completed, it should be carefully checked to avoid the wrong connection before the power is turned on.
Cable specification: Considering that the cable is immersed in water (including sea water) for a long time or exposed to the air, all the wiring points are required to do waterproof treatment, the user cable should has certain corrosion resistance.
The cleanliness of the measuring window is very important for maintaining accurate readings.
Maintenance task | Recommended maintenance frequency |
Calibrate sensors (If required by the competent authority) | According to the maintenance schedule required by the competent department |
Sensor outer surface: clean the outer surface of the sensor with tap water, if there is still debris residue, wipe with wet soft cloth, for some stubborn dirt, you can add some household washing liquid to tap water to clean.
Check the cable of the sensor: the cable should not be tightened when it is working properly, otherwise it is easy to break the wire inside the cable and make the sensor unable to work properly.
Check the sensor measurement window if there is any dirt, cleaning brush is normal.
The probe contains sensitive optical and electronic components. Make sure the probe is not subjected to severe mechanical impact. There are no components inside the probe that need to be maintained by the user。
a)Zero calibration: take proper amount of zero turbidity solution with large beaker, put the sensor vertically in the solution, the front end of the sensor is at least 10 cm from the bottom of the beaker, and the zero calibration will be carried out after the value is stabilized for 3-5 minutes. The instructions refer to the appendix.
b)Slope calibration: the sensor probe is placed in the standard solution, the front end of the sensor is at least 10 cm from the bottom of the beaker, and the slope calibration is carried out after 3 -5 minutes of numerical stability. The instructions refer to the appendix.
Prev:NBL-TPS-206 Online Transparency Water Quality Sensor
Next:NBL-RDO-206 Online Fluorescence Dissolved Oxygen Sensor
Sensors & Weather Stations Catalog
Agriculture Sensors and Weather Stations Catalog-NiuBoL.pdf
Weather Stations Catalog-NiuBoL.pdf
Related recommendations
Screenshot, WhatsApp to identify the QR code
WhatsApp number:+8615367865107
(Click on WhatsApp to copy and add friends)