Our online multi-parameter self-cleaning digital water quality sensor is designed with an integrated structure, ensuring reliability and ease of use. It can measure up to 8 parameters simultaneously, including dissolved oxygen, COD, pH, ORP, conductivity/salinity, ammonia nitrogen, turbidity, etc. The sensor uses the RS-485 bus and Modbus/RTU communication protocol, with data directly transmitted to the collection platform. The self-cleaning mechanism of the sensor can be set···
Tel/WhatsApp:+8615367865107
Email:Arvin@niubol.com +Nearly 100 partner companies in more than 75 countries. We are committed to providing high-quality, practical products to meet your needs and help you solve problems. Our products comply with international standards and are certified with ISO, CE and RoHS.Product Details
Product Overview: The NiuBoL NBL-WQ-MPS-5A is a self-cleaning multiparameter water quality sensor designed for integrated online monitoring. It supports configurable measurement modules for dissolved oxygen (DO), chemical oxygen demand (COD), pH, oxidation-reduction potential (ORP), electrical conductivity or salinity, ammonia nitrogen and turbidity. Depending on the ordered configuration, the integrated assembly supports up to eight measurement parameters, including temperature.
The multiparameter probe includes an automatic cleaning system, removable sensing modules and RS485 Modbus RTU communication. The complete assembly operates from 12 VDC ±5%, with a specified power consumption of 5 W at 12 V.
Water quality monitoring projects often require several measurements at the same location. Installing separate probes for every parameter can increase the number of mounting positions, communication connections and maintenance tasks.
The NBL-WQ-MPS-5A integrates selected water quality sensing modules into one probe assembly. A common RS485 Modbus RTU interface provides access to the installed measurement channels.
The sensor modules can be selected according to the application. Available measurement families include dissolved oxygen, COD, pH, ORP, conductivity or salinity, ammonia nitrogen and turbidity.
The integrated design supports up to eight parameters, including temperature. The actual measurement combination depends on the modules and configuration supplied with the order.
An automatic cleaning brush helps remove deposits from the sensing region. The protective cover has openings that allow water contact while reducing direct mechanical exposure of the internal probes.
This design is suitable for compatible wastewater treatment, environmental monitoring, aquaculture and industrial water monitoring projects where multiple measurements are required at one location.
Configurable multiparameter monitoring: Select the measurement channels required for the application.
Up to eight parameters: Maximum documented combination includes temperature.
Integrated automatic cleaning brush: Adjustable cleaning intervals and rotation cycles.
Modular sensor construction: Quick-release waterproof connectors for compatible sensing modules.
RS485 Modbus RTU: Digital data acquisition through a shared communication interface.
Protective sensor cover: Slotted design allows contact with water while offering mechanical protection.
12 VDC power supply: Specified supply voltage for the complete multiparameter assembly.
5 W power consumption: Rated value at 12 VDC.
Standard 5-meter cable: Other lengths can be specified for the monitoring installation.
Independent sensor maintenance: Calibration and inspection can be performed according to the requirements of each installed sensing module.
The NBL-WQ-MPS-5A supports several optional measurement modules. Select the appropriate sensor configuration according to the monitoring objective, measurement range and water conditions.
| Measurement Module | Available Range | Resolution |
|---|---|---|
| Dissolved Oxygen (DO) | 0–20 mg/L | 0.01 mg/L |
| Turbidity | 0–100 NTU | 0.1 NTU |
| Turbidity | 0–1000 NTU | 0.1 NTU |
| Electrical Conductivity | 0–5000 µS/cm | 1 µS/cm |
| Electrical Conductivity | 0–200 mS/cm | 0.1 mS/cm |
| Salinity | 0–70 PSU | 0.1 PSU |
| Chemical Oxygen Demand (COD) | 0–200 / 0–500 mg/L KHP Equivalent | 0.1 mg/L |
| pH | 0–14 pH | 0.01 pH |
| ORP | -1500 to +1500 mV | 1 mV |
| Ammonia Nitrogen | 0–100 / 0–1000 mg/L | 0.1 mg/L |
| Temperature | 0–50°C | 0.1°C |
Configuration: The ranges above describe available measurement-module options, not simultaneous outputs supplied with every probe. The final channel combination, module quantities and measurement ranges are defined by the ordered configuration.
Conductivity and salinity belong to the same measurement family. Confirm the required output parameter and units when selecting that module.
| Parameter | Specified Accuracy |
|---|---|
| Dissolved Oxygen | ±2% |
| Turbidity, 0–100 NTU | ±3% or ±2 NTU |
| Turbidity, 0–1000 NTU | ±5% or ±3 NTU |
| Conductivity / Salinity | ±1.5% F.S. |
| COD | ±5% F.S. |
| COD Module Turbidity | ±5% F.S. |
| pH | ±0.1 pH |
| ORP | ±6 mV |
| Ammonia Nitrogen | ±10% or ±2 mg/L |
| Temperature | ±0.3°C |
Measurement accuracy depends on the selected module and its operating conditions. Resolution and accuracy are different specifications.
For projects requiring formal acceptance testing, the required accuracy, measurement units, reference procedures and calibration conditions should be defined for each selected parameter.
The optional COD module uses a calibrated optical method to estimate COD-related concentration. It is available with two paired COD and turbidity ranges.
| COD Range | Built-In Turbidity Range |
|---|---|
| 0–200 mg/L KHP Equivalent | 0–100 NTU |
| 0–500 mg/L KHP Equivalent | 0–200 NTU |
COD readings from the optical module are based on a potassium hydrogen phthalate (KHP) calibration relationship. They are not automatically identical to results from laboratory COD digestion methods.
Where agreement with laboratory COD measurements is important, evaluate the optical response using representative water samples.
The built-in turbidity channel of the COD module should also be distinguished from a separately installed turbidity measurement module when configuring the data acquisition system.
| Parameter | Specification |
|---|---|
| Brand | NiuBoL |
| Model | NBL-WQ-MPS-5A Self-Cleaning Multiparameter Water Quality Sensor |
| Product Type | Integrated Online Multiparameter Water Quality Probe |
| Maximum Measurement Parameters | Up to 8, Including Temperature |
| Sensor Configuration | Selectable Measurement Modules |
| Cleaning Method | Integrated Automatic Cleaning Brush |
| Digital Output | RS485 Modbus RTU |
| Power Supply | 12 VDC ±5% |
| Power Consumption | 5 W @12 VDC |
| Temperature Measurement Range | 0–50°C |
| Temperature Accuracy | ±0.3°C |
| Temperature Resolution | 0.1°C |
| Default Cleaning Interval | 30 Minutes |
| Adjustable Cleaning Interval | 6–6000 Minutes |
| Default Cleaning Rotations | 3 |
| Adjustable Cleaning Rotations | 0–10 |
| Default Modbus Address | 6 (0x06) |
| Default Communication Settings | 9600 bps, 8N1 |
| Standard Cable Length | 5 m; Custom Lengths Available |
| Cable | 4-Core Shielded Twisted-Pair Cable |
| Sensor Connector | M16 Waterproof Connector |
| Approximate Overall Length | 400 mm |
| Approximate Maximum Diameter | 100 mm |
| Mounting | Lifting Ring or Compatible Mechanical Mounting Arrangement |
Power requirement: The 12 VDC ±5% specification applies to the complete MPS-5A assembly. Do not use the wider voltage range or lower consumption of a standalone water quality sensor when powering the multiparameter probe.
The approximate dimensions are intended for mounting assessment. The final mounting arrangement should match the supplied assembly and selected sensor configuration.
The NBL-WQ-MPS-5A combines multiple sensing technologies in one assembly rather than using one universal measurement principle.
Different parameters require different sensing methods:
Dissolved oxygen: Measurement of oxygen dissolved in water.
pH: Electrochemical measurement of acidity or alkalinity.
ORP: Measurement of oxidation-reduction potential.
Conductivity / salinity: Measurement or reporting of dissolved ionic properties.
COD: Optical estimation of COD-equivalent concentration.
Ammonia nitrogen: Ion-selective measurement of ammonia-related nitrogen.
Turbidity: Optical measurement of light scattering associated with suspended particles.
Temperature: Water temperature measurement.
The selected sensing modules communicate through the integrated system, which makes the corresponding values available over a common Modbus RTU connection.
Each measurement module has its own calibration requirements and measurement limitations.
The multiparameter assembly simplifies the communication and mounting arrangement, but it does not remove the need to select the correct method for each water quality parameter.
The NBL-WQ-MPS-5A includes an automatic cleaning device designed to help reduce deposits on the installed sensing region.
During continuous water monitoring, suspended matter and biological growth can accumulate on exposed sensor surfaces.
The cleaning system operates according to configurable cleaning intervals and rotation cycles.
| Setting | Value |
|---|---|
| Cleaning Interval Register | 0x1300 |
| Default Interval | 30 Minutes |
| Adjustable Interval | 6–6000 Minutes |
| Cleaning Rotation Register | 0x1301 |
| Default Rotations | 3 |
| Adjustable Rotations | 0–10 |
| Restore Cleaning Defaults | 0x2020 |
Cleaning frequency should be selected according to the monitored water and expected fouling conditions.
The cleaning brush can help reduce some manual cleaning work, but it does not eliminate periodic inspection, calibration or replacement of consumable sensing components.
For monitoring locations with heavy sediment, biological growth or chemical deposits, maintenance access remains important.
Not every monitoring station needs every available water quality parameter.
The correct module combination depends on the decisions the monitoring system needs to support.
| Application | Parameters to Consider | Selection Consideration |
|---|---|---|
| Municipal Wastewater | DO, pH, ORP, COD, Ammonia Nitrogen | Process location, water composition and expected ranges |
| Aquaculture | DO, Temperature, pH, Conductivity / Salinity | Species requirements, water type and monitoring location |
| River Monitoring | Temperature, DO, pH, Turbidity, Conductivity | Seasonal water conditions, fouling and installation access |
| Industrial Water | pH, ORP, Conductivity, COD as Applicable | Chemical compatibility and measurement method suitability |
These are configuration examples rather than fixed packages. The final combination must be compatible with the available assembly capacity and the selected modules.
For COD monitoring, confirm whether the required result is an optical COD-equivalent estimate or a measurement accepted under a specific analytical method.
For ammonia nitrogen monitoring, define the required reporting units and consider possible ionic interference.
An integrated multiparameter probe can simplify installation when several measurements are required at one location.
However, separate sensors may be preferable when different parameters require different installation conditions.
| Selection Factor | Multiparameter Probe | Separate Sensors |
|---|---|---|
| Measurement Location | Several parameters at one position | Independent positions for different parameters |
| Communication | Shared RS485 Modbus interface | Separate sensor addresses and wiring |
| Maintenance | Integrated probe inspection and module servicing | Individual sensor servicing |
| Power Supply | 12 VDC ±5%, 5 W for MPS-5A | Depends on each selected sensor |
| Expansion | Limited by available compatible module positions | Additional sensors can use separate mounting arrangements |
The suitable approach depends on the measurement location, installation space, service access and required data acquisition architecture.
The NBL-WQ-MPS-5A is designed as an integrated water quality probe assembly.
The protective cover permits water access to the installed measurement modules while helping protect them from mechanical contact.
The probe can be secured using a suitable lifting ring or compatible mechanical mounting arrangement.
Choose a representative water monitoring location.
Secure the assembly using appropriate mounting hardware.
Do not use the electrical cable as the primary mechanical support.
Ensure that the installed sensing modules remain properly immersed during measurement.
Maintain sufficient clearance from nearby structures and sediment.
Protect the probe from mechanical impact and excessive movement.
Provide access for module replacement, calibration and cleaning.
Waterproof all field electrical connections.
Verify the compatibility of all wetted materials with the monitored water.
For applications involving seawater, aggressive chemicals or significant water pressure, assess the complete sensor assembly, including individual measurement modules, connectors, seals and cable materials.
The complete NBL-WQ-MPS-5A assembly requires a regulated 12 VDC ±5% power supply.
The sensor uses a four-core shielded cable for power and RS485 communication.
| Wire Color | Function |
|---|---|
| Red | 12 VDC Positive |
| Black | Ground (GND) |
| Blue | RS485 A |
| White | RS485 B |
Power planning: The rated consumption is 5 W at 12 VDC for the multiparameter assembly. For solar-powered monitoring stations, include the data logger, communication gateway, cable losses and operating power reserve in the system design.
Verify the supply voltage and wire connections before applying power.
The NBL-WQ-MPS-5A communicates with compatible PLCs, RTUs and data loggers through RS485 Modbus RTU.
| Communication Parameter | Default Setting |
|---|---|
| Interface | RS485 |
| Protocol | Modbus RTU |
| Baud Rate | 9600 bps |
| Data Bits | 8 |
| Parity | None |
| Stop Bits | 1 |
| Default Device Address | 6 (0x06) |
| Address Range | 1–255 |
| Read Function Code | 03 |
| Write Function Code | 06 |
Each measurement channel uses two consecutive 16-bit registers: one for the raw measurement value and one for its decimal-place scaling.
| Starting Address | Measurement Channel |
|---|---|
| 0x0000 | Temperature |
| 0x0002 | COD |
| 0x0004 | COD Module Built-In Turbidity |
| 0x0006 | Conductivity / Salinity |
| 0x0008 | pH |
| 0x000A | ORP |
| 0x000C | Dissolved Oxygen |
| 0x000E | Ammonium-Related Measurement |
| 0x0010 | Turbidity |
The register map defines available channel positions. A register address does not mean that every measurement module is installed in the supplied probe.
When an optional module is absent, its channel may return zero. The data acquisition system should distinguish an uninstalled measurement channel from a valid zero concentration.
The following request reads 18 registers starting at address 0x0000 from device address 6:
Request: 06 03 00 00 00 12 C4 70
For example, a temperature data pair of 00 A3 00 01 represents a raw value of 163 with one decimal place, giving 16.3°C.
Use the individual register values and decimal scaling information when decoding each installed measurement channel.
| Register | Function |
|---|---|
| 0x1300 | Set Automatic Cleaning Interval |
| 0x1301 | Set Cleaning Rotations |
| 0x2002 | Set Main Modbus Device Address |
| 0x2020 | Restore Cleaning Brush Default Settings |
The NBL-WQ-MPS-5A also supports module-specific calibration and communication settings.
Calibration operations should use the correct module, reference solution, register address and scaling. Do not apply one sensor module's calibration procedure to another measurement channel.
The NBL-WQ-MPS-5A provides measurement data through RS485 Modbus RTU.
NBL-WQ-MPS-5A → RS485 Modbus RTU → PLC / RTU / Data Logger → Monitoring Software
For remote monitoring, a separate compatible communication gateway can transmit the acquired data to a receiving platform or server.
The multiparameter probe itself is not a complete 4G or cloud monitoring station.
During commissioning, configure the receiving system with the correct device address, installed measurement channels, units and decimal scaling.
Record which optional modules are installed so that unconfigured channels are not incorrectly displayed as valid measurements.
The NBL-WQ-MPS-5A includes an automatic cleaning brush, but each measurement module still requires appropriate maintenance.
Inspect the protective cover, cleaning brush, installed sensor modules, waterproof connectors and main cable.
Check for excessive deposits, biological growth or mechanical damage.
Rinse the probe exterior with clean tap water. For remaining deposits, gently clean accessible surfaces with a soft, damp cloth.
Follow the appropriate cleaning method for each installed sensing module.
Different modules may require different calibration solutions and procedures.
For example, pH calibration differs from conductivity, dissolved oxygen, COD and ammonia nitrogen calibration.
Use the calibration procedure appropriate to the selected module and monitoring requirements.
Inspection and calibration intervals should be adjusted to the water conditions and required measurement quality.
A1. The multiparameter assembly supports up to eight parameters, including temperature. The actual measurement combination depends on the installed modules.
A2. No. The required measurement modules and ranges should be selected when ordering.
A3. Yes. The integrated cleaning brush supports adjustable cleaning intervals and rotations.
A4. No. Automatic cleaning can help reduce deposits, but sensor modules still require inspection and calibration.
A5. The complete multiparameter assembly requires 12 VDC ±5%, with a specified power consumption of 5 W at 12 V.
A6. Yes. The default settings include 9600 baud, 8 data bits, no parity, one stop bit and device address 6.
A7. The optional COD module provides a COD-equivalent measurement and an associated turbidity channel. The installed modules and selected ranges must be confirmed for the ordered assembly.
A8. No. The optical COD measurement uses a KHP-equivalent calibration relationship. Agreement with laboratory COD depends on water composition and reference comparison.
A9. Yes. Compatible PLCs, RTUs and data loggers can read the available measurement channels through RS485 Modbus RTU.
A10. The MPS-5A provides RS485 Modbus RTU. Remote cellular communication requires a separate compatible data logger or communication gateway.
A11. It can be considered for compatible wastewater monitoring applications. The required modules, measurement ranges, chemical conditions and maintenance requirements should be evaluated before selection.
A12. Provide the required measurement parameters, ranges, water type, installation conditions, cable length, quantity and receiving monitoring system.
Download the complete NBL-WQ-MPS-5A user manual for module specifications, installation dimensions, wiring, Modbus register addresses, automatic cleaning settings and calibration procedures.
NBL-WQ-MPS-5A Online Multi-parameter Self-cleaning Water Quality Sensor.pdf
For accurate product selection and quotation, please provide:
Required parameters: DO, COD, pH, ORP, conductivity/salinity, ammonia nitrogen, turbidity or other required measurements.
Measurement ranges: Normal and maximum expected values for each parameter.
Application: Wastewater treatment, aquaculture, river monitoring, reservoir monitoring or industrial water.
Water conditions: Temperature, chemical composition, solids, fouling and installation conditions.
Installation: Mounting arrangement, monitoring location and available maintenance access.
Communication: Receiving PLC, RTU, data logger or communication gateway model.
Power supply: Available 12 VDC supply and complete monitoring-station power requirements.
Order details: Required cable length, quantity and destination country.
Please indicate whether the quotation should cover only the multiparameter sensor assembly or a complete water quality monitoring station with separate data acquisition, communication and power equipment.
For a different integrated sensor configuration, see the NBL-WQ-MPS-5B Self-Cleaning Multiparameter Water Quality Sensor.
Explore additional NiuBoL Online Water Quality Sensors for individual and multiparameter monitoring applications.
Prev:Online Water pH Sensor RS485 Modbus | NBL-WQ-PH
Next:Water Conductivity EC Sensor RS485 Modbus IP68 | NBL-WQ-EC
Sensors & Weather Stations Catalog
Agriculture Sensors and Weather Stations Catalog-NiuBoL.pdf
Weather Stations Catalog-NiuBoL.pdf
Agriculture Sensors Catalog-NiuBoL.pdf
Water Quality Sensor Catalog-NiuBoL.pdf
Related recommendations
Online Turbidity Sensor RS485 Modbus | NBL-WQ-TS
Online Ammonia Nitrogen Sensor (Ammonium ISE) | NBL-WQ-NHN
Online Residual Chlorine Sensor (HOCl) RS485 | Water Quality Sensor| NBL-WQ-CL
NBL-WQ-DO Online Fluorescence Dissolved Oxygen Sensor
NBL-WQ-COD Online COD Water Quality Sensor
Water Conductivity EC Sensor RS485 Modbus IP68 | NBL-WQ-EC
Screenshot, WhatsApp to identify the QR code
WhatsApp number:+8615367865107
(Click on WhatsApp to copy and add friends)