Call Phone +8618073152920 Hotline: +8618073152920
Call Phone +8618073152920
English
CONTACT US/ CONTACT US
Consumer hotline +8618073152920
Changsha Zoko Link Technology Co., Ltd.

Email:Arvin@niubol.com

WhatsApp:+8615367865107

Address:Room 102, District D, Houhu Industrial Park, Yuelu District, Changsha City, Hunan Province, China

Position:Home >> Blogs >> Company news

Company news

CO2 and Illuminance Sensors Exported to Cambodia

Time:2022-09-08 22:05:42 Popularity:1874

NiuBoL exported CO2 and illuminance sensors to Cambodia. The two instruments supply separate environmental measurements: carbon dioxide concentration in the surrounding air and visible-light illuminance at the sensing position. They can form part of greenhouse, building or environmental monitoring systems when their ranges and installation conditions match the project.

NiuBoL carbon dioxide and illuminance sensor export to Cambodia

Two channels with different jobs

Carbon dioxide monitoring can help operators observe how air conditions change with ventilation, occupancy or greenhouse operation. Illuminance monitoring records the light level on a defined plane. Reading both channels in one acquisition system makes their trends easier to compare, but neither channel alone describes the entire growing environment or building air quality.

For a greenhouse, CO2 concentration can change when vents open or injection equipment operates, while illuminance responds to daylight, shading and lamps. For buildings, the measurements support different ventilation and lighting assessments. The system designer should therefore assign separate channel names, units and control rules rather than treating them as a single environmental score.

NiuBoL NBL-W-CO2 carbon dioxide sensor for environmental monitoring

Sensor options for similar Cambodia projects

MeasurementCO2 sensor optionIlluminance sensor option
Product familyNBL-W-CO2NBL-W-LUX
Measurement range0-5000 ppm0-200000 lux
Supply12-24 V DC12-24 V DC
Output versions4-20 mA or RS4854-20 mA, 0-5 V or RS485

These are product-family options for a comparable new order, not a specification of the electrical versions in the Cambodia export. Select the required range and output before connecting a sensor to a PLC or data logger. An RS485 input also needs the matching communication protocol and register interpretation; an analog input needs the correct current or voltage scaling.

Install the CO2 sensing point in air representative of the monitored zone, away from a concentrated injection plume or ventilation jet unless that stream is the measurement target. Place the illuminance sensor on the plane being assessed and avoid shadows from mounting hardware. Direct rain, condensation and cabinet cable entries need protection appropriate to the exact sensor version and location.

NiuBoL NBL-W-LUX illuminance sensor for environmental data acquisition

From environmental readings to a usable system

A data logger can timestamp both measurements and pass them to a gateway or local monitoring interface. If the project includes automatic ventilation or lighting control, the controller and actuators must be specified as separate parts of the package. The sensor order alone does not provide those control functions.

Illuminance in lux is not a substitute for PAR or PPFD when an experiment requires plant-light measurements. Likewise, an environmental CO2 transmitter should not be specified as a certified gas-safety alarm without the required approvals and alarm performance. Selecting the correct measured quantity avoids an unsuitable purchase even when the electrical connection is compatible.

For a similar Cambodia project, send NiuBoL the application, expected CO2 and light levels, indoor or outdoor exposure, power supply, output type and receiving controller. The CO2 sensor and illuminance sensor can then be reviewed as individual field instruments or as inputs to a wider acquisition system.

Related recommendations

Sensors & Weather Stations Catalog

Agriculture Sensors and Weather Stations Catalog-NiuBoL.pdf

Weather Stations Catalog-NiuBoL.pdf

Agriculture Sensors Catalog-NiuBoL.pdf

Water Quality Sensor Catalog-NiuBoL.pdf

Related products

Tell us your requirements, Let's discuss more about your project.we can do more.

Name*

Tel*

Email*

Company*

Country*

Message


online
Contacts
Email
Top
XCO2 and Illuminance Sensors Exported to Cambodia-Company news-Automatic Weather Stations_Industrial, Agricultural, Water & Environmental IoT Monitoring Solutions—NiuBoL

Screenshot, WhatsApp to identify the QR code

WhatsApp number:+8615367865107

(Click on WhatsApp to copy and add friends)

Open WhatsApp

The WhatsApp ID has been copied, please open WhatsApp to add consultation details!
WhatsApp