CO2 sensor cost includes the specified transmitter and the work required to obtain a usable reading from it. For the NiuBoL NBL-W-CO2, confirm the 2000 or 5000 ppm range, RS485 Modbus RTU or 4-20 mA output, receiving input and cable before comparing quotations. A replacement that fits mechanically can still require different scaling or acquisition settings.

An environmental contractor replacing an existing CO2 transmitter has a different purchasing task from an integrator building a new monitoring point. The first may retain the supply and controller. The second may also need an acquisition channel, enclosure, communication equipment and commissioning. A sensor-only unit price does not describe both projects.
Request an itemized NiuBoL quotation for the ordered range, output, cable and quantity. Identify any configuration, testing or accessories included. Prices depend on the ordered configuration and included work. Obtain a current quotation before preparing a budget or repeat purchase.
| NBL-W-CO2 item | Specification | Cost or replacement implication |
|---|---|---|
| 2000 ppm version | 0-2000 ppm; +/-(40 ppm + 2% F.S.) | Check expected concentrations and the full-scale accuracy term |
| 5000 ppm version | 0-5000 ppm; +/-(50 ppm + 3% of reading) | Do not replace the reading-based term with a full-scale term |
| Resolution | 1 ppm | A displayed increment is not 1 ppm accuracy |
| Supply / consumption | 12-24 V DC; approximately 0.2 W | Check the installed supply and other station loads separately |
| Output alternatives | RS485 Modbus RTU or 4-20 mA | Select the version that the receiving equipment can use |
| Current-output load | Load resistance no greater than 250 ohms | Review the receiving circuit before retaining it |
| Operating environment | -10 to 50 degree C; 0-100%RH | Check the actual installation, including condensation and airflow |
| Standard cable / mass | 2.5 m; approximately 140 g | Specify cable and mounting needs before ordering |
At a 1000 ppm reading, the 2000 ppm version's stated expression gives +/-80 ppm: 40 + 0.02 x 2000. The 5000 ppm expression gives +/-80 ppm at that reading too, but +/-125 ppm at 2500 ppm. These calculations interpret the specified expressions; they are not field-test results or proof that the versions are interchangeable.

For the current-output version, concentration equals (current in mA - 4) / 16 multiplied by the selected full-scale concentration. At 12 mA, a 2000 ppm transmitter represents 1000 ppm, while a 5000 ppm transmitter represents 2500 ppm. An unchanged controller scale would therefore turn a correct current into the wrong concentration.
Before ordering a replacement, record the existing transmitter range, input type, wiring and receiving scale. Check whether the controller permits the required change and who will implement it. Include an end-to-end input test in the work scope. Changing a label on the dashboard does not change the analog conversion.
The concentration-trend illustration below is not a calibration report. Use controlled checks and the final saved data to establish whether an installed channel meets the project's requirement.

The digital version supports RS485 Modbus RTU, a default 9600 bps rate, eight data bits and no parity. The specified interval between communications is at least 1000 ms. Confirm the supplied address, stop-bit setting and register interpretation with the receiving PLC, RTU or data logger.
The communication example returns data bytes 01 B4, representing 436 ppm. This is a concentration value, not a temperature channel requiring division by ten. For a multi-point project, demonstrate the settings on a sample sensor before configuring repeated units. Keep commissioning instructions with the approved version so later replacements do not depend on a technician remembering an earlier installation.
An appropriate installed analog channel may favor the 4-20 mA version. An available compatible Modbus acquisition path may favor RS485. Neither is universally cheaper: a new input module, cable run or integration visit can change the installed cost. Review actual spare capacity rather than assuming the controller supports every signal printed in a product catalogue.
Where the project needs several environmental quantities, compare that requirement separately with a combined sensor. The CO2 sensor price comparison for combined environmental equipment discusses that broader decision. A multi-parameter assembly is not automatically a direct replacement for a standalone CO2 transmitter.

The NBL-W-CO2 transmitter measures concentration at its installed point. Keep air circulation around its ventilated enclosure. A location immediately beside a dosing outlet, open door or supply-air jet can produce a reading that does not represent the intended greenhouse or room. Correcting a poor position later can require another cable run and site visit.
Specify the cable length when ordering rather than extending or changing factory wiring without agreement. Allow access for inspection and replacement. Do not seal the ventilated body inside a cabinet that prevents the intended sample air from reaching it. A listed humidity range does not, by itself, establish performance under condensation or direct liquid exposure.
For an inquiry, provide the expected concentration range, receiving controller, output type, supply, cable route and whether this is a new point or a replacement. NiuBoL can then distinguish the transmitter supply from the additional integration work. No fixed service interval, replacement life or savings percentage should be assumed without an agreed basis.

No. Select the range for expected concentrations and the required measurement performance. The two versions also use different accuracy expressions; compare them at the concentrations that matter to the application.
Not without checking the receiving scale. The same current represents different concentrations. Confirm wiring, load, range and the controller conversion before putting the replacement into service.
It provides RS485 Modbus RTU measurements. Remote access requires compatible acquisition and communication equipment plus a receiving application, quoted separately where needed.
No. A CO2 measurement output does not establish a complete or certified protective alarm system. Applications with safety requirements need separately specified equipment and applicable approval evidence.
Include the approved model, range, output, supply, cable and quantity, together with any changes to the receiving system. Identify the tested configuration rather than relying on "same CO2 sensor" alone.
NBL-W-CO2-Carbon-Dioxide-Sensor-Instruction-Manual-2000ppm.pdf
NBL-W-CO2 Carbon-Dioxide-Sensor-Instruction-Manual-5000ppm.pdf
Compare CO2 sensor cost around the actual NBL-W-CO2 version and installed work. Range interpretation, receiving inputs and service access can matter more than a small difference in unit price. Request a configuration-specific quotation and verify the complete measurement path before repeat procurement.
Related recommendations
Sensors & Weather Stations Catalog
Agriculture Sensors and Weather Stations Catalog-NiuBoL.pdf
Weather Stations Catalog-NiuBoL.pdf
Agriculture Sensors Catalog-NiuBoL.pdf
Water Quality Sensor Catalog-NiuBoL.pdf
Related products
Combined air temperature and relative humidity sensor
TDR Soil Moisture & Temperature Sensor for irrigation| RS485 |4-20mA| NBL-S-THR
Soil pH sensor RS485 soil Testing instrument soil ph meter for agriculture |NBL-S-PH
Wind Speed sensor Output Modbus/RS485/Analog/0-5V/4-20mA
Tipping bucket rain gauge for weather monitoring auto rainfall sensor RS485/Outdoor/stainless steel
Pyranometer Solar Radiation Sensor 4-20mA/RS485
Screenshot, WhatsApp to identify the QR code
WhatsApp number:+8615367865107
(Click on WhatsApp to copy and add friends)