— Blogs —
—Products—
Consumer hotline +8618073152920 WhatsApp:+8615367865107
Address:Room 102, District D, Houhu Industrial Park, Yuelu District, Changsha City, Hunan Province, China
Product knowledge
Time:2026-08-26 09:07:00 Popularity:339
Quick Answer: A 5-in-1 weather station package is only suitable when its five named measurements match the project. NiuBoL NBL-W-51MUWS measures wind speed, wind direction, temperature, humidity and pressure. NBL-W-THPLC instead combines temperature, humidity, pressure, illuminance and CO2. Neither label guarantees rainfall, solar irradiance, a logger or wireless upload. Write the required channels first, then choose the sensing arrangement.

A package described only as five-in-one leaves a contractor with an incomplete equipment schedule. Wind speed and direction may count as two measurements; another package may substitute rainfall or light. The count also says nothing about whether a display, data logger, power system or mounting structure is supplied.
Convert the requirement into named channels with units and purpose. For example, an outdoor wind assessment may require m/s and direction in degrees alongside ambient temperature, relative humidity and pressure. A greenhouse environmental point may need CO2 and visible-light level instead of wind. Equal channel counts do not make these configurations substitutes.
| Project requirement | Relevant configuration | What remains outside that choice |
|---|---|---|
| Five-channel outdoor weather observation | NBL-W-51MUWS: wind speed, wind direction, temperature, humidity, pressure | Rainfall, radiation and any soil measurements |
| Ambient environment with CO2 and illuminance | NBL-W-THPLC: temperature, humidity, pressure, illuminance, CO2 | Wind and rainfall; illuminance is not irradiance |
| Independent sensor positions | A modular combination of suitable instruments | Additional supports, wiring and acquisition requirements |
| Remote access | A compatible logger or gateway and selected network | Not automatically included inside a sensing head |
The higher-parameter head pictured below is a different configuration. Its appearance does not identify which functions are enabled in an offer. A substitution needs a named model and channel list, not an assurance that a larger number must cover the original requirement.

A compact head reduces separate field connections and can suit a monitoring point whose variables share an acceptable location. Its limitation is physical: wind and ambient channels move together. If the installation needs independent exposure or easier replacement of one measurement, separate instruments may justify their extra mounting work.
For a farm with an outdoor wind point and indoor crop-environment observations, do not place one combined head at an intermediate location to compromise between both. Use a weather point outside and suitable environmental measurements inside. A signal bus can join their records without requiring them to share a bracket.
For rainfall, decide whether a separate gauge is needed and where it can be maintained. Adding rainfall to the data list does not make NBL-W-51MUWS a rain sensor. For photovoltaic monitoring, specify irradiance and the relevant measurement plane; a lux channel cannot be renamed W/m2. These decisions should precede selection of the logger inputs.
The NBL-W-51MUWS ultrasonic integrated sensor provides a concrete five-channel option. The following details apply to that head, not to every product sold with a five-parameter description. Keep the sensing range distinct from the operating limits of the complete instrument.
| Item | NBL-W-51MUWS detail | Selection consequence |
|---|---|---|
| Wind speed | 0-40 m/s; accuracy +/-(0.5 m/s + 2% FS) | Check expected extremes and the required uncertainty |
| Wind direction | 0-360 degrees; accuracy +/-3 degrees | Provide a geographic north reference and suitable exposure |
| Temperature accuracy | +/-0.5 degrees C | Installation exposure still affects representativeness |
| Humidity | 0-100% RH; accuracy +/-5% RH | Do not infer continuous condensation tolerance from range coverage |
| Pressure | 500-1100 hPa; accuracy +/-1.5 hPa | Check the expected station pressure, especially at elevation |
| Supply and average power | 12 V DC; 0.3 W | Logger and remote communications are separate loads |
| Output | RS485 Modbus; 9600 bps | Obtain the delivered Modbus RTU data definition |
| Operating environment | -40 to 80 degrees C; 0-95% RH; IP65 | Use the assembly limits rather than a wider individual channel range |
| Housing and lead | ABS; standard 2.5 m cable | Review the actual route, cable specification and protected termination |
At 0.3 W continuously, the head alone uses 7.2 Wh over 24 hours. This is arithmetic using the stated average load, not a complete station energy budget. Add the acquisition device, network equipment, conversion losses and any separately powered instruments before selecting batteries or solar equipment.
A five-channel name does not establish suitability for a structural wind-safety system or a certified meteorological reference. If the project has a prescribed standard, accuracy class or safety requirement, identify it explicitly and assess the complete proposed arrangement against it. Do not infer that approval from protocol compatibility.

A separate cup anemometer can be positioned independently and paired with a suitable direction sensor. It introduces moving components, another support and additional connections. An ultrasonic head avoids rotating cups, but its sensing paths must remain unobstructed and the whole head may need attention if a channel is unavailable.
Compare replacement work rather than assuming one design always has a lower maintenance cost. Ask which components can be serviced separately, what configuration is needed after replacement and whether the site can reach them safely. Availability of a spare sensor is useful only if the installation permits a practical change.
The cup sensor pictured below measures speed, not direction. If it replaces the wind-speed part of a five-channel arrangement, retain or provide the direction measurement separately. Use IP65 for the specified NiuBoL wind-speed and wind-direction sensors, and protect the logger and field connections according to their own ratings.

A complete data point needs an acquisition device able to read the chosen signals. A PLC, RTU or data logger may provide that function. For RS485 Modbus RTU instruments, check supply, serial settings, supported addresses and register conversion for each model. More than one compatible instrument can share an engineered bus, but duplicate addresses or mismatched settings prevent reliable polling.
Remote transmission is another layer. Choose the implemented Ethernet, cellular or other supported link around the site and receiving system. State whether the destination is a supplier platform or a private server. A quoted radio or modem does not establish the payload, account access, storage or outage recovery behaviour.
For the first installation, inspect an actual export. Confirm channel names, units, observation times and unavailable-data states. Wind direction needs directional processing, not an ordinary average of degree values across north. Accumulated rainfall, if supplied by a separate gauge, needs its own reset and interval handling. These are software tasks, not extra physical measurements supplied by the five-channel head.
Ask for two clearly bounded alternatives when the layout is uncertain: the chosen integrated head and a modular arrangement meeting the same required observations. List included instruments, supports, cables, acquisition, power and configuration. Identify existing equipment that can remain. A larger station is not an improvement when its added channels have no defined use.
The NBL-W-THPLC environmental sensor below is relevant when CO2 and illuminance are required. It is not an alternative wind station. Check its own range and supply version, then assess where the CO2 and light observations must be made. Shared environmental channels do not justify using one model's specification for the other.
For a quotation, provide the intended decision, required channels, normal and extreme site conditions, sensor positions and existing receiving equipment. Include required data intervals and the destination. Those details expose a missing measurement early, when changing the configuration is easier than adding another mast or recabling an installed station.

Not necessarily. NBL-W-51MUWS counts wind speed and direction separately and includes pressure, not rainfall. Specify every required variable by name rather than relying on the count.
No. NBL-W-THPLC provides a different channel set. It may suit an environmental point that needs CO2 and illuminance, but it does not provide the missing wind measurements.
Use them when independent exposure, individual replacement or a required measurement method justifies the extra installation and acquisition work. Confirm that the resulting arrangement actually solves that problem rather than adding hardware by habit.
The described RS485 sensing head needs a compatible acquisition and communications path. Confirm the logger, network module and destination separately. A weather-station package name does not establish their inclusion.
Compare named channels, ranges, accuracy expressions, supply, mounting and data format. Read the values at the intended receiver and check the unavailable indication. A similar enclosure or a higher channel count is insufficient.
A 5-in-1 weather station package should be selected from its measurements and placement, not its label. Choose the NiuBoL five-channel configuration that answers the project question, add separate instruments only where needed, and specify acquisition and remote access as distinct functions. A channel-by-channel enquiry produces a usable offer without paying for an unsuitable combination.
Prev:Portable Dissolved Oxygen and BOD Meter: When to Add Online DO
Next:Portable Water Quality Meter: Prevent Carryover Between Sites
Related recommendations
Sensors & Weather Stations Catalog
Agriculture Sensors and Weather Stations Catalog-NiuBoL.pdf
Weather Stations Catalog-NiuBoL.pdf
Agriculture Sensors Catalog-NiuBoL.pdf
Water Quality Sensor Catalog-NiuBoL.pdf
Related products
Combined air temperature and relative humidity sensor
TDR Soil Moisture & Temperature Sensor for irrigation| RS485 |4-20mA| NBL-S-THR
Soil pH sensor RS485 soil Testing instrument soil ph meter for agriculture |NBL-S-PH
Wind Speed sensor Output Modbus/RS485/Analog/0-5V/4-20mA
0.2mm Tipping Bucket Rain Gauge for Weather & Hydrology | NiuBoL
Pyranometer Solar Radiation Sensor 4-20mA/RS485
Screenshot, WhatsApp to identify the QR code
WhatsApp number:+8615367865107
(Click on WhatsApp to copy and add friends)