— Blogs —
—Products—
Consumer hotline +8618073152920 WhatsApp:+8615367865107
Address:Room 102, District D, Houhu Industrial Park, Yuelu District, Changsha City, Hunan Province, China
Product knowledge
Time:2026-08-16 09:00:00 Popularity:221
Quick answer: When choosing a rain gauge supplier for Malaysia, separate the instrument supply from local installation, logger configuration and maintenance. An imported sensor can fit an existing station if its measurement method, output and records meet the project requirement. It does not automatically include a Malaysian service team, a communications subscription or site commissioning. Ask NiuBoL to itemize those responsibilities before comparing offers.

A contractor adding rainfall to an existing drainage-monitoring cabinet needs a different quotation from a distributor supplying a complete agricultural weather station. State the project location, measurement purpose, available power and receiving logger. Include a site drawing or photographs showing obstructions, mounting access and cable routes. The country name alone cannot establish the required intensity range, installation exposure or service interval.
For a gauge-only purchase, identify who will count pulses or read registers. For a complete station, include local recording, communications and export requirements. For repeat supply through a distributor, identify the approved model and output version so a replacement can be installed without redesigning the input channel.
The six-parameter unit above includes a piezoelectric rainfall channel. It is a compact weather sensor, not a stainless-steel tipping-bucket gauge. The choice changes both mechanical installation and the test used to check the rainfall channel.
| Item | NBL-W-RS tipping bucket | NBL-W-61MUWS integrated sensor |
|---|---|---|
| Rainfall principle | Collected water tips a mechanical bucket | Piezoelectric raindrop-impact detection |
| Intensity range | 0-4 mm/min | 0-8 mm/min |
| Resolution | 0.2 mm; 6.28 mL per tip | 0.01 mm reported rainfall resolution |
| Accuracy statement | +/-4% under indoor static testing at 2 mm/min | +/-10% |
| Supply | 5 V or 12-24 VDC according to version | 12-24 VDC |
| Output | Reed switch, voltage or RS485 versions | RS485 Modbus RTU |
| Operating temperature | 0-50 C | -20 to 50 C |
| Consumption / protection | Confirm for the ordered assembly; do not borrow another model's rating | Approximately 0.35 W average; IP65 |
| Standard cable | 5 m | 2.5 m |
These accuracy statements are not a common field-comparison result. The RS test condition must remain attached to its percentage, and finer reported resolution does not prove better rainfall accuracy. Ask for the applicable test procedure and the expected site operating envelope. Confirm cable-jacket material, connector sealing and any enclosure separately.
The seven-parameter sensor below adds either solar radiation or illuminance to weather and rainfall measurements. Select the light measurement explicitly; it is not supplied as both channels in the standard configuration.

Ask for separate lines for the gauge, cable and connector, mounting hardware, logger input configuration and any gateway. Then identify the party responsible for installing the base, routing the cable, commissioning the record and maintaining the inlet or impact surface. A product warranty is not the same service as an on-site visit.
For a Malaysian distributor or engineering contractor, useful support includes an output definition before cabinet fabrication, model-specific test instructions and a clear route for diagnosing a fault. Request spare-part availability and the procedure for returning an instrument when local repair is not appropriate. Agree on these details for the order rather than assuming a local stockholding or response time.
The eight-parameter model pictured next measures wind, temperature, humidity, pressure, particulate matter and noise. It has no rainfall channel in its standard configuration. More parameters in the name do not necessarily satisfy a rainfall tender.

For a tipping bucket, manual tipping can verify the logger's pulse count and conversion. It does not establish hydraulic accuracy. A controlled water test must use the relevant setup and delivery rate. For the piezoelectric channel, mechanical tapping or pouring an arbitrary volume onto the housing is not an equivalent calibration procedure; obtain the appropriate functional and comparison method.
For either version, check the final stored rainfall, interval boundaries, units and behavior after a restart. For RS485 Modbus RTU, confirm the ordered register definition and whether each rainfall field is cumulative or interval-based. A dashboard value without a defined interval is difficult to compare with a site reference.
The ten-parameter unit below includes rainfall along with additional environmental channels. Choose it when those other measurements have an identified use, not as an assumed upgrade for rainfall accuracy.

Submit the logger model, input type, power supply and required rainfall record. Compatibility needs checking against the ordered pulse, voltage or RS485 version; a complete new station is not always necessary.
No. The standard NBL-W-81GUWS eight-parameter model does not. Check the actual channel list rather than the number in the product name.
No. Compare the instrument, logger work, installation, communications, transport and agreed service scope separately. Request a current itemized quotation; no single public price represents all of those configurations.
Confirm the rainfall method, intensity range, exposure, input compatibility, cable route and acceptance test. Identify who performs and records commissioning, and how site staff will obtain service parts.
No. Ask for the current dispatch schedule, destination arrangements and support responsibilities in the quotation. Do not infer local inventory, a named Malaysian agent or on-site service from a product listing.

A comparable rain-monitoring offer identifies the actual rainfall instrument and the local work required to make its data useful. Send NiuBoL the site and logger information, then compare the proposed hardware, installation and service responsibilities as separate parts of the purchase.
Prev:Water Quality Monitoring Equipment Replacement: Keep Old and New Records Separate
Next:Smart Home Soil Moisture Sensor for Managed Gardens: What Must Work Offline?
Related recommendations
Sensors & Weather Stations Catalog
Agriculture Sensors and Weather Stations Catalog-NiuBoL.pdf
Weather Stations Catalog-NiuBoL.pdf
Agriculture Sensors Catalog-NiuBoL.pdf
Water Quality Sensor Catalog-NiuBoL.pdf
Related products
Combined air temperature and relative humidity sensor
TDR Soil Moisture & Temperature Sensor for irrigation| RS485 |4-20mA| NBL-S-THR
Soil pH sensor RS485 soil Testing instrument soil ph meter for agriculture |NBL-S-PH
Wind Speed sensor Output Modbus/RS485/Analog/0-5V/4-20mA
Tipping bucket rain gauge for weather monitoring auto rainfall sensor RS485/Outdoor/stainless steel
Pyranometer Solar Radiation Sensor 4-20mA/RS485
Screenshot, WhatsApp to identify the QR code
WhatsApp number:+8615367865107
(Click on WhatsApp to copy and add friends)