— Blogs —
—Products—
Consumer hotline +8618073152920 WhatsApp:+8615367865107
Address:Room 102, District D, Houhu Industrial Park, Yuelu District, Changsha City, Hunan Province, China
Product knowledge
Time:2026-08-23 09:00:00 Popularity:256
A 5-in-1 weather station replacement starts with five named measurements, not the number printed on a housing. One NiuBoL five-parameter device measures wind speed, wind direction, temperature, humidity and pressure. Another five-parameter environmental sensor measures temperature, humidity, pressure, illuminance and CO2. The second cannot replace a wind alarm, and the first cannot supply greenhouse CO2. A project buyer should map the old channels to required decisions before choosing an integrated sensor.

Ask the operator for a point list and one month of representative data. Which measurements drive a PLC, irrigation schedule, site alarm or report? Which only appear on a local display? Identify units, update intervals, alarm thresholds, mounting location and data owner. A new station may add channels that no one needs while omitting rainfall, solar radiation or a signal type required by an existing controller. The cost of that mismatch can be greater than the sensor price.
The first linked image shows the NBL-W-THPLC, which measures temperature, humidity, pressure, illuminance and CO2. It may suit greenhouse or ambient-environment monitoring where those five variables matter, but it is not the five-channel wind sensor discussed in most outdoor weather-station replacements. Its illuminance reading in lux is also not a solar-irradiance reading in W/m2. Put the required measurement names and units into the RFQ rather than specifying only '5-in-1'.
| NiuBoL model shown | Measured channels | Replacement implication |
|---|---|---|
| NBL-W-THPLC | Temperature, humidity, pressure, illuminance, CO2 | Environmental or greenhouse duty; no wind or rainfall channel. |
| NBL-W-51MUWS | Wind speed, wind direction, temperature, humidity, pressure | Five basic outdoor meteorological channels; no built-in rainfall. |
| NBL-W-61MUWS | The five meteorological channels plus rainfall | Consider when the old station's rain record is operationally required. |
| NBL-W-71GUWS | Wind, air, pressure, rainfall plus solar radiation or illuminance | Specify which seventh light parameter is ordered; they are alternatives. |
| NBL-W-81GUWS | Wind, air, pressure, PM2.5, PM10, noise | Air-quality and noise duty; do not assume rainfall is included. |
This comparison is a channel map, not a claim that every listed product is interchangeable. The models have different sensing methods, electrical specifications and service needs. Select from the current model datasheet after the required channels are fixed. A modular station with separate sensors may be preferable if one channel needs a different exposure, replacement cycle or measurement principle.
The NBL-W-51MUWS is NiuBoL's integrated outdoor wind-speed, wind-direction, temperature, humidity and pressure sensor. Its product page lists ultrasonic wind measurement, RS485 Modbus RTU output, 12-24 VDC supply and IP65 protection. Those are sensor specifications, not a complete station package: mast, enclosure, logger, power system and remote communications must be itemized separately. The sensor itself does not make a 4G or cloud connection without suitable equipment.
For a replacement on a farm or industrial site, check whether the existing wind reference and mounting height can be retained. Moving a sensor from an open mast to a roof edge may change the wind record even when both instruments are accurate. Nearby buildings, trees, exhausts and sun-heated surfaces can bias different channels in different ways. Record the old and new location, height and orientation; do not merge their time series as though the exposure were unchanged.
Ultrasonic wind measurement has no rotating cups or vane, but the sensor head still needs cleaning and physical inspection. Rain, ice, debris or birds can affect an exposed installation depending on site conditions. Where a wind alarm supports a safety procedure, validate the full threshold, delay, notification and operator response. A general weather sensor alone is not an approval for safety-critical shutdown.

If the old station's rainfall channel drives irrigation or drainage decisions, an NBL-W-51MUWS alone is incomplete. The NBL-W-61MUWS adds rainfall using a piezoelectric impact method within an integrated head. That may reduce separate mounting hardware, but its rain principle is not identical to a tipping-bucket gauge. A project with a historical tipping-bucket series or a specified rainfall standard should examine resolution, intensity range, siting and correlation requirements before replacing the gauge.
Rain measurement needs an unobstructed position. Wind shields, mast geometry, nearby foliage and roofs can affect catch or impact detection. A compact integrated head puts wind and rain at one location, which may not be the preferred exposure for both. A separate rain gauge and wind sensor can be justified when the site or acceptance standard needs distinct positions or independent servicing. The RFQ should say whether the priority is installation simplicity or a particular measurement method.

The NBL-W-71GUWS adds one selectable light measurement to wind, temperature, humidity, pressure and rainfall. Solar radiation in W/m2 and illuminance in lux are not interchangeable. A photovoltaic performance or evapotranspiration project should state the radiation quantity and required sensor class; a public lighting application may need illuminance. Confirm the ordered seventh channel on both quotation and Modbus register list before installation.
The NBL-W-81GUWS addresses a different job: wind, temperature, humidity and pressure together with PM2.5, PM10 and environmental noise. It is not simply a more capable rain station. If a replacement project needs both rainfall and particulate measurements, confirm an appropriate combination or modular design; do not infer that the highest parameter count contains every lower-numbered channel. For regulated particulate or acoustic reporting, verify applicable reference-method and calibration requirements separately from a general environmental-monitoring instrument.

Map each old point to the new model's actual register, data type, scaling and unit. RS485 is the physical interface; Modbus RTU registers are model-specific. A replacement can appear online while wind direction is decoded as speed or pressure is displayed with the wrong scale. Test all channels through the actual PLC, RTU, logger or gateway. Confirm whether the legacy station supplied instantaneous wind, an average or a gust, and whether rain was an interval value, pulse count or daily total. These are not interchangeable labels.
For remote telemetry, specify the full route from sensor to logger, modem and platform. Confirm local buffering when the network fails, time synchronization, data ownership and export format. If a home-style console was previously used for a public display, decide whether a new private logger should supply the display or whether the display can consume the integrator's data feed. A cloud screenshot is not evidence that the buyer can retrieve the data later.
Power should be sized for the chosen sensor, logger, modem and expected transmission schedule. A solar panel that runs a simple five-channel node may not cover a continuously transmitting station with particulate sensing. Request a site-specific energy budget and autonomy target. The quotation should list sensor model, mast and brackets, power system, enclosure, cabling, surge protection where required, gateway or logger, software access and commissioning. No universal fixed price can be inferred from a '5-in-1' label because these scopes differ.

Where possible, run the old and new stations in parallel for a defined period. Compare channels only when their positions, heights, averaging intervals and units are known. Investigate systematic differences before changing historical baselines or alarms. Keep the old hardware available until the new system has passed communication, timestamp, power-restart and alarm tests. A one-day parallel run may expose mapping errors but will not prove seasonal equivalence.
At handover, record the selected model and ordered parameter variant, mounting location and orientation, register map, as-built wiring, sample readings, platform access and maintenance responsibility. If a separate rain gauge or radiation sensor was added, list those separately. The acceptance record should make clear which five or more variables are actually delivered, rather than repeating a marketing shorthand.
No. NBL-W-51MUWS measures wind speed, wind direction, temperature, humidity and pressure. NBL-W-THPLC measures temperature, humidity, pressure, illuminance and CO2. Compare named channels and units, not only the count.
No. If rainfall is required, evaluate a model such as NBL-W-61MUWS or a separate rain gauge. Choose the method according to the project's rainfall record and acceptance requirements.
No. Lux and W/m2 represent different physical quantities. Specify the parameter required by the photovoltaic, agronomic or lighting calculation and verify the ordered variant.
No. NBL-W-81GUWS adds particulate and noise channels and does not automatically include the rainfall or light channels of another model. Compare the complete point list before selecting a variant.
Check supply, RS485 wiring, address, serial settings, register mapping, scaling, units and timestamp for every channel. Exercise alarms and restart behavior through the receiving PLC or logger, not only at the sensor.
Only if differences in sensor exposure, height, sampling and aggregation are documented and accepted. Parallel observations help identify discontinuities, but a short comparison does not establish full equivalence.
Required channels, integrated versus modular arrangement, mast and exposure work, power, telemetry, data platform and commissioning scope. Request an itemized offer rather than comparing standalone sensor prices with complete station packages.
A 5-in-1 weather station replacement succeeds when the new channels match the old system's actual decisions and the data route remains testable. NiuBoL offers distinct integrated sensor configurations for basic meteorology, rainfall, light and environmental monitoring. Name the variables, choose the appropriate model and accept the installed data point by point before retiring the previous station.
Prev:Connected Rodent Pest Control: Separate Trap and Insect Monitoring
Next:Water Quality Monitoring Device: Investigate an Alarm Before Resetting It
Related recommendations
Sensors & Weather Stations Catalog
Agriculture Sensors and Weather Stations Catalog-NiuBoL.pdf
Weather Stations Catalog-NiuBoL.pdf
Agriculture Sensors Catalog-NiuBoL.pdf
Water Quality Sensor Catalog-NiuBoL.pdf
Related products
Combined air temperature and relative humidity sensor
TDR Soil Moisture & Temperature Sensor for irrigation| RS485 |4-20mA| NBL-S-THR
Soil pH sensor RS485 soil Testing instrument soil ph meter for agriculture |NBL-S-PH
Wind Speed sensor Output Modbus/RS485/Analog/0-5V/4-20mA
Tipping bucket rain gauge for weather monitoring auto rainfall sensor RS485/Outdoor/stainless steel
Pyranometer Solar Radiation Sensor 4-20mA/RS485
Screenshot, WhatsApp to identify the QR code
WhatsApp number:+8615367865107
(Click on WhatsApp to copy and add friends)