Quick Answer: Use a TDS and pH tester to verify the final mixed water, not to assume that both values follow the blend ratio. Conductivity-derived TDS depends on ionic composition and its conversion setting; pH also depends on acid-base chemistry and buffering. A satisfactory TDS result does not establish a satisfactory pH result.

A TDS and pH tester is useful where a plant blends incoming water sources or combines treated water with another supply. Operators may change the proportions to meet a process requirement. The final decision concerns the water delivered to the process, not just separate readings from the two feed pipes.
Measure the inputs to understand what changed, then verify the final mixture after adequate exchange and mixing. Do not average the two pH values by their volume proportions. pH is logarithmic, and buffering and reactions affect the final result; knowing only the two feed pH readings is insufficient to calculate a dependable mixed-water pH.
For TDS, distinguish a mass-balance estimate from a conductivity conversion. A weighted dissolved-mass calculation requires an appropriate measurement basis and assumptions about reactions and losses. Two EC-derived TDS numbers do not automatically provide that basis, particularly when the two waters have different ionic compositions or use different coefficients.

The pH probe above measures an acid-base condition; the EC probe at the beginning measures electrical conductance and can provide a supported TDS estimate. They are separate instruments, not a single combined handheld tester. NiuBoL's online probes can connect to a compatible PLC, RTU or data logger for repeated records of a blending point.
| Requirement | NBL-WQ-EC | NBL-WQ-PH |
|---|---|---|
| Measurement | Conductivity; derived TDS where supported | pH by glass electrode |
| Range | Four EC choices from 0-20.00 uS/cm to 0-200.0 mS/cm; select the version | 0-14 pH |
| Accuracy | +/-1% FS for EC | +/-0.1 pH |
| Temperature / pressure | 0-50 C; <0.6 MPa | 0-65 C; <0.2 MPa |
| Supply / consumption | 12-24 VDC +/-10%; 0.2 W at 12 V | 12-24 VDC; 0.2 W at 12 V |
| Interface / protection | RS485 Modbus RTU; IP68 | RS485 Modbus RTU; IP68 |
| Materials / mounting / cable | ABS, default SUS316L or PVC by configuration; 3/4 NPT; standard 5 m | POM; 3/4 NPT; standard 5 m |
Confirm wetted-material and cable-jacket compatibility with both feed waters and cleaning conditions. Do not put the pH probe on a line selected only against the EC pressure rating. EC uses Pt1000 temperature compensation in this family; the base pH model uses NTC compensation. Neither makes all chemical changes with temperature disappear.

The BOD probe above is a separate optional measurement, not a way to validate the blend's TDS or pH. Define the actual blended-water monitoring point before adding other parameters. A probe directly beside one inlet may see that stream before the other has mixed into it.
At changing blend ratios, account for travel and tank replacement time before comparing a feed observation with the outlet. Check low-flow as well as normal operation, because the mixing pattern can change. Record valve or flow information where it exists; do not assume the monitoring probe measures the blend proportion independently.
The turbidity channel below may help identify particles introduced or formed during mixing. A clear-looking blend, however, can still have an unsuitable dissolved-ion concentration or pH. Conversely, turbidity cannot be converted into a TDS correction to make an otherwise uncertain mixture appear acceptable.

Verify EC in a suitable conductivity standard and pH in appropriate buffers before checking process samples. Then observe the intended blend conditions under the site's approved operating procedure. Compare final-water samples with suitable reference measurements, using compatible temperature and reporting conventions.
Keep the EC observation behind the TDS display and record the applied coefficient. If feed chemistry changes, investigate whether the conversion remains useful before adjusting it. A pH correction or blending adjustment can alter conductivity as chemicals are added, so evaluate each channel against its own process requirement.
The ammonium-selective probe below is relevant only when the project has a nitrogen-specific requirement. It does not establish total nitrogen, complete chemical composition or general suitability of reused water. Additional sensor purchases should follow an identified risk rather than a desire to make the package look complete.

Display EC or TDS and pH as separate channels with their own validity and operating limits. If the pH probe is removed for service, a normal EC value cannot authorize a decision that requires both. The PLC or operator procedure must define what to do when one required measurement is unavailable.
Likewise, dissolved oxygen below answers an oxygen question, not a pH or salt-balance question. For an enquiry, provide the two feed-water descriptions, expected blend conditions, required final-water values, pressure, temperature and controller interface. Ask for a sample comparison where composition or measurement suitability is uncertain.

No. Volume-weighted pH averaging is not a reliable blending rule. Buffering and acid-base reactions matter; measure or appropriately model the final mixture using the necessary chemistry.
No. Different ion mixtures can produce similar conductivity-derived TDS. Check the composition and process requirements that determine suitability, not just the displayed estimate.
No. These measurements do not identify all chemical or microbiological hazards. Apply the required water-quality tests and acceptance rules for the intended use.
Only when the measurement bases and conditions are compatible. Check compensation settings, sample timing and mixing; compensation does not remove reactions or unrepresentative sampling.
No. Separate online EC and pH probes can serve the task with compatible acquisition. Their holders, ranges and service requirements must still suit the final-water point.
Only for its separately defined measurement purpose. The COD probe below supplies an optical organic-load indicator, not a replacement for pH, dissolved-ion assessment or a complete water-suitability test.

A TDS and pH tester helps verify blended water when both channels represent the final mixture and their meanings remain separate. Select the NiuBoL EC and pH versions against the actual operating envelope, test the intended blends and avoid inferring composition or safety from two plausible numbers.
Prev:TDS Measurement Instrument: Preserve Records When Conversion Settings Change
Next:Dissolved Oxygen Sensor in Water: Interpret Aeration On/Off Transitions
Related recommendations
Sensors & Weather Stations Catalog
Agriculture Sensors and Weather Stations Catalog-NiuBoL.pdf
Weather Stations Catalog-NiuBoL.pdf
Agriculture Sensors Catalog-NiuBoL.pdf
Water Quality Sensor Catalog-NiuBoL.pdf
Related products
Combined air temperature and relative humidity sensor
TDR Soil Moisture & Temperature Sensor for irrigation| RS485 |4-20mA| NBL-S-THR
Soil pH sensor RS485 soil Testing instrument soil ph meter for agriculture |NBL-S-PH
Wind Speed sensor Output Modbus/RS485/Analog/0-5V/4-20mA
Tipping bucket rain gauge for weather monitoring auto rainfall sensor RS485/Outdoor/stainless steel
Pyranometer Solar Radiation Sensor 4-20mA/RS485
Screenshot, WhatsApp to identify the QR code
WhatsApp number:+8615367865107
(Click on WhatsApp to copy and add friends)